Evidence map›Paper›PMID 41465372›Full record

ArticleInternational journal of molecular sciences2025

Combination of Noble Metal and Gold-Silver Nanoclusters as Enhanced Antibacterial Coatings for Ti-Based Medical Implants.

Evgeniia S Vikulova, Svetlana I Dorovskikh, David S Sergeevichev, Tatiana Ya Guselnikova, Anastasiya D Fedorenko, Alexander A Zheravin, Natalya B Morozova

Abstract read
In one paragraph

Article in International journal of molecular sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Evgeniia S VikulovaNikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 3 Lavrentiev Ave., 630090 Novosibirsk, Russia.
Svetlana I DorovskikhNikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 3 Lavrentiev Ave., 630090 Novosibirsk, Russia.ORCID 0000-0002-1314-3065
David S SergeevichevE. Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 15 Rechkunovskaya Str., 630055 Novosibirsk, Russia.ORCID 0000-0002-5027-6561
Tatiana Ya GuselnikovaNikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 3 Lavrentiev Ave., 630090 Novosibirsk, Russia.ORCID 0000-0003-3584-9074
Anastasiya D FedorenkoNikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 3 Lavrentiev Ave., 630090 Novosibirsk, Russia.ORCID 0000-0002-4833-4582
Alexander A ZheravinE. Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 15 Rechkunovskaya Str., 630055 Novosibirsk, Russia.
Natalya B MorozovaNikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 3 Lavrentiev Ave., 630090 Novosibirsk, Russia.

Funding

Russian Science Foundation 25-15-00328
6 · The paper itself

Abstract

The surface modification of medical implant materials stands as a favorable strategy to enhance their biological properties including their antibacterial effect and biocompatibility. Recently, both in vitro and in vivo studies have shown that film heterostructures based on a combination of noble metal sublayers and an active component, such as silver and gold nanoparticles, offer unique advantages. The present work develops this promising direction and focuses on a series of combinations of noble metal coatings functionalized with bimetallic nanoclusters obtained by vapor-phase deposition methods onto the surfaces of Ti-based implants. This investigation investigates the influence of sequential deposition (AgAu or AuAg) and noble metal component (Ir or Au) on the coating morphology and the active component chemical form and release. Thus, scanning electron microscopy, X-ray photoelectron spectroscopy, and inductively coupled plasma atomic emission spectroscopy have been applied to characterize the samples before and after in vivo biological studies (rat models, 1 and 3 months). Histological and blood analyses confirmed the high biocompatibility of all the heterostructures. The samples also showed a pronounced in vitro biocidal effect against Gram-positive (

Indexed as

Anti-Bacterial AgentsCoated Materials, BiocompatibleGoldMetal NanoparticlesProstheses and ImplantsSilverTitaniumAnimalsMicrobial Sensitivity TestsPseudomonas aeruginosaRatsAnti-Bacterial AgentsCoated Materials, BiocompatibleGoldSilverTitaniumAgAu nanoclustersantibacterial activitychemical vapor depositionfilm heterostructureshistological studynoble metalsphysical vapor depositiontitanium alloy implants

Identifiers

PMID41465372
PMCPMC12732423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.