Evidence map›Paper›PMID 41463658›Full record

ArticleBioengineering (Basel, Switzerland)2025

Wearable PPG Multi-Sensor for Skin Humidity, Temperature, and Contact Pressure Measurement in Weak Magnetic Field Environment: First-Step Experiments.

Jiří Přibil, Anna Přibilová, Tomáš Dermek

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jiří PřibilInstitute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia.ORCID 0000-0002-7488-1643
Anna PřibilováInstitute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia.ORCID 0000-0002-5107-2552
Tomáš DermekInstitute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia.

Funding

Slovak Scientific Grant Agency VEGA2/0004/23
6 · The paper itself

Abstract

This study describes the developed special prototype of a wearable measuring device based on a photoplethysmography (PPG) sensor. It contains also a humidity sensor and a thermometer to measure skin moisture and temperature, and a force-sensitive (FSR) element to sense a contact pressure between the measuring probe and the skin surface. All parts of the multi-sensor are shielded, to be applicable in a weak magnetic field environment. After the basic sensor's functionality verification inside the magnetic resonance imaging tomograph, a set of experiments was performed. Comparative measurements by an oximeter confirm good correspondence with heart rate values determined from PPG (

Indexed as

contact pressure force measurementskin humidity and temperaturewearable photoplethysmography optical sensor

Identifiers

PMID41463658
PMCPMC12730050

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.