Evidence map›Paper›PMID 41462409›Full record

ArticleInternational journal of retina and vitreous2025

Concentric macular rings and OCT corrugations in foveal hypoplasia: proof of concept for an optical interference mechanism.

Ari H August, Ralph C Eagle, Tatyana Milman, Rebecca Procopio, Bruce M Schnall, José S Pulido

Abstract read
In one paragraph

Article in International journal of retina and vitreous, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Haidinger's brushes in albinism: altered perception patterns in single cases.Documenta ophthalmologica. Advances in ophthalmology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ari H AugustDepartment of Ophthalmology, Sidney Kimmel Medical College of Thomas Jefferson University, 1025 Walnut St #100, Philadelphia, PA, 19107, USA. aaugust@willseye.org.ORCID http://orcid.org/0000-0001-6650-8147
Ralph C EagleDepartment of Ophthalmology, Sidney Kimmel Medical College of Thomas Jefferson University, 1025 Walnut St #100, Philadelphia, PA, 19107, USA.ORCID http://orcid.org/0000-0001-8408-5010
Tatyana MilmanDepartment of Ophthalmology, Sidney Kimmel Medical College of Thomas Jefferson University, 1025 Walnut St #100, Philadelphia, PA, 19107, USA.ORCID http://orcid.org/0000-0003-4015-7195
Rebecca ProcopioWills Eye Hospital, 840 Walnut Street, Philadelphia, PA, 19107, USA.ORCID http://orcid.org/0000-0001-7994-8088
Bruce M SchnallWills Eye Hospital, 840 Walnut Street, Philadelphia, PA, 19107, USA.ORCID http://orcid.org/0009-0005-9629-5281
José S PulidoDepartment of Ophthalmology, Sidney Kimmel Medical College of Thomas Jefferson University, 1025 Walnut St #100, Philadelphia, PA, 19107, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundConcentric macular rings (CMR) and Henle fiber layer (HFL) corrugations, potential clinical biomarkers of foveal hypoplasia, have been observed in laser fundus photographs and optical coherence tomography (OCT) images, respectively. Some believe these findings represent true anatomical structural changes while others hypothesize that they are artifacts of interference; however, to our knowledge, no previous study has provided evidence to support either theory.

methodsThis retrospective case series analyzed CMR and OCT corrugations in 3 patients (6 eyes) with foveal hypoplasia. Dark fringe diameters of CMR at different wavelengths (λ: red = 635, green = 532, blue = 488 nm) and OCT corrugations of the first five dark fringes were measured. Dark fringe diameter was compared to fringe order (n) and λ using linear regression and t-tests.

resultsCMR fringe measurements demonstrated linear relationships between radius2 (r2) and fringe order at all wavelengths (mean R2: 0.949, SD: 0.022, range: 0.911–0.985). OCT corrugation measurements also exhibited strong linearity with fringe order (R2 = 0.998, 0.946). Fringe r2 increased with wavelength but exceeded theoretical predictions (p < 0.05), especially among ratios including shorter λ (mean difference r2 red:green = 0.104, green:blue = 0.292, red:blue = 0.468).

conclusionsThis study is the first to provide evidence supporting an etiologic mechanism of CMR and HFL corrugations, showing correlation with physical phenomena of interference. CMR and HFL corrugations correlate with fringe order (n) and λ in a manner consistent with Newton’s rings (r2 = nR’λ, r = radius, R’ = radius of curvature), suggesting these phenomena are imaging artifacts. Further research validating these results will be important.

trial registrationThis study does not report the results of a health care intervention on human participants. CLINICAL TRIAL DISCLOSURE: This study does not report results of a clinical trial.

Indexed as

FingerprintingFoveal hypoplasiaImaging artifactInterferenceMacular ripplesNewton’s ringsOCT corrugationsOculocutaneous albinismOphthalmic imagingOptical coherence tomographyRetinal imagingScanning laser ophthalmoscopy

Identifiers

PMID41462409
PMCPMC12752041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.