Evidence map›Paper›PMID 41462179›Full record

ArticleBMC musculoskeletal disorders2025

Biomechanical comparison of two fixation constructs for displaced quadrilateral surface acetabular fractures: a finite elements analysis.

Xi Hou, Haofei Wang, Zihan Liu, Haoyuan Fu, Zhiyong Hou, Yingze Zhang, Ruipeng Zhang

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Influence of endplate degeneration on fusion process in lateral lumbar interbody fusion.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xi HouDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Haofei WangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Zihan LiuDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Haoyuan FuDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Zhiyong HouDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Yingze ZhangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
Ruipeng ZhangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China. 38900330@hebmu.edu.cn.

Funding

2025 Hebei Province Government-funded Training Program for Clinical Medical Professionals ZF2025138National Natural Science Foundation of China 82202682
6 · The paper itself

Abstract

backgroundAcetabular fractures involving the quadrilateral surface demonstrate increasing prevalence and pose substantial challenges in orthopedic management. While stable fixation is essential to prevent complications such as post-traumatic arthritis, the optimal surgical technique for complex fractures, particularly those affecting the quadrilateral surface, remains controversial. This finite element analysis evaluates the comparative biomechanical performance and clinical utility of acetabular quadrilateral surface plates (AQSP) versus conventional reconstruction plates in treating acetabular T-type fractures.

methodsThis study employed finite element analysis (FEA) to evaluate the biomechanical performance of two fixation methods: the conventional reconstruction plate and the AQSP. Three-dimensional models of T-type acetabular fractures were constructed and subjected to simulated physiological loading conditions, with stress distribution, displacement patterns, and implant stability assessed through quantification of von Mises stress, contact pressure, and displacement magnitudes.

resultsThe AQSP exhibited superior mechanical stability relative to the conventional reconstruction plate, demonstrating more uniform stress distribution and reduced displacement. Quantitative analysis revealed enhanced stability metrics for the AQSP, including lower von Mises stress (37.99 MPa) and diminished displacement (0.39 mm).

conclusionThe AQSP provides enhanced biomechanical stability for quadrilateral surface fracture fixation compared to conventional reconstruction plates. Its optimized stress distribution and reduced displacement establish the AQSP as a viable alternative for improving clinical outcomes in complex acetabular fractures.

Indexed as

AcetabulumBone PlatesFinite Element AnalysisFracture Fixation, InternalFractures, BoneBiomechanical PhenomenaHumansStress, MechanicalAcetabular fracturesAnatomical quadrilateral surface plateFinite element analysisMechanical stabilityReconstruction plate

Identifiers

PMID41462179
PMCPMC12752443

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.