Agreement between IOL Master 700 and Pentacam in measuring total keratometry and posterior keratometry across different axial lengths in cataract patients.

Zhi-Yong Tian, Peng Zhao, Zhong-Yan Li, Zhi Chen, Jing-Shang Zhang, Ying-Yan Mao, Xiu-Hua Wan, Meng Li

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhi-Yong TianBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.
Peng ZhaoShandong Second Medical University, Weifang, 261000, Shandong, China.
Zhong-Yan LiShandong Second Medical University, Weifang, 261000, Shandong, China.
Zhi ChenBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.
Jing-Shang ZhangBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.
Ying-Yan MaoBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.
Xiu-Hua WanBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China. xiuhuawan@163.com.
Meng LiBeijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China. drlimeng@mail.ccmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to systematically evaluate the consistency of total keratometry (TK) and posterior keratometry (PK) measurements obtained by the IOL Master 700 and Pentacam in cataract patients with varying axial lengths (AL).

methodsA total of 240 cataract patients (240 eyes) were recruited from Beijing Tongren Hospital between February and April 2025. Participants were categorized into six groups based on AL: < 22 mm, 22-24 mm, 24-26 mm, 26-28 mm, 28-30 mm, and ≥ 30 mm. All patients underwent preoperative examinations using the IOL Master 700 and Pentacam systems to obtain measurements of TK and PK. The paired t-test or Wilcoxon signed-rank test was employed to evaluate intergroup differences. The Bland-Altman analysis was conducted to assess the 95% limits of agreement (LoA), with calculation of the mean difference.

resultsExcept for the subgroup with AL < 22 mm, the TK measured by the IOL Master 700 was significantly higher than that obtained using the Pentacam across all AL subgroups. The mean difference ranged from 0.005D to 0.406 D, with the width of the 95% LoA varying between 1.071D and 2.382D. For PK, measurements obtained by the IOLMaster 700 were significantly flatter compared to those from the Pentacam across all subgroups. The mean differences ranged from 0.442 to 0.478 D, with the width of the 95% LoA ranging from 0.244 to 0.319 D.

conclusionRegardless of AL, the measurement discrepancies in TK and PK between the two devices exceed the clinically acceptable limits, suggesting that these devices are not interchangeable across patients with varying AL.