Evidence map›Paper›PMID 41459870›Full record

ArticleAsian Pacific journal of cancer prevention : APJCP2025

Assessment of TrueBeam kV Cone-Beam CT Image Quality and the Clinical Impact of Calibration Drift.

C O Clinto, B Bindhu

Abstract read
In one paragraph

Article in Asian Pacific journal of cancer prevention : APJCP, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

C O ClintoDepartment of Physics, Noorul Islam Centre for Higher Education, Kumaracoil, Kanyakumari, Tamil Nadu, India.ORCID 0000-0002-7473-1696
B BindhuDepartment of Physics, Noorul Islam Centre for Higher Education, Kumaracoil, Kanyakumari, Tamil Nadu, India.ORCID 0000-0002-0577-0923

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study compared the image quality of the TrueBeam (TB) kilo-voltage cone-beam CT (CBCT) system using standard reconstruction (TB-sCBCT) and iterative reconstruction (TB-iCBCT) with that of the Halcyon iterative CBCT (H-iCBCT). Additionally, the clinical impact of calibration drift over a one-year period was investigated for both head and pelvis imaging modes.

methodsImage quality and calibration were assessed using the Catphan®. Image quality evaluation included the analysis of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and low-contrast detectability. Calibration stability for head and pelvis CBCT modes was examined by comparing dose-volume histogram (DVH) parameters across ten tongue and ten prostate patient cases.

resultsThe average SNR was 3.1 for TB-sCBCT, 23.1 for TB-iCBCT, and 6.9 for H-iCBCT, while the corresponding CNR values were 11.2, 53.0, and 28.4, respectively. At a contrast level of 0.3%, the smallest detectable target diameters were 15 mm for TB-sCBCT, 8 mm for TB-iCBCT, and 9 mm for H-iCBCT. Over a one-year period, the Hounsfield Unit (HU) variation in the head CBCT mode exceeded the recommended action threshold of ±50 HU, whereas the pelvis CBCT mode remained within acceptable limits.

conclusionIn the TB system, advanced iterative reconstruction algorithms significantly enhance SNR and CNR by effectively reducing image noise. Halcyon provides improved image quality compared to TB with standard reconstruction; however, it remains inferior to TB-iCBCT. HU deviations were more pronounced in head CBCT than in pelvis mode, although HU variation in the pelvis CBCT mode exhibited greater sensitivity regarding clinical impact.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedProstatic NeoplasmsRadiographic Image Interpretation, Computer-AssistedTongue NeoplasmsAlgorithmsCalibrationHumansMalePelvisPhantoms, ImagingPrognosisRadiotherapy Planning, Computer-AssistedSignal-To-Noise Ratiocalibration driftCBCT image qualityiterative reconstruction

Identifiers

PMID41459870
PMCPMC13245262

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.