Implementation of Guidelines and a Decision Support Tool for Blood Glucose Monitoring Device Prescriptions in Saudi Arabia: Compliance Assessment and Potential Cost Savings and Coverage Expansion.

Lamya Alzubaidi, Faisal Elenezi, Amera S Alrshood, Abdullah Alsoheimi, Abdullah M Arabe, Muna Hassan Mustafa Hassanein

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lamya AlzubaidiAda'a Health Center, Ministry of Health, Riyadh, SAU.
Faisal EleneziHospitals Services Assistant Agency, Ministry of Health, Riyadh, SAU.
Amera S AlrshoodAda'a Health Center, Ministry of Health, Riyadh, SAU.
Abdullah AlsoheimiGeneral Directorate of Specialized Centers Affairs, Ministry of Health, Riyadh, SAU.
Abdullah M ArabeGeneral Directorate of Specialized Centers Affairs, Ministry of Health, Riyadh, SAU.
Muna Hassan Mustafa HassaneinTraining and Institutional Development Department, Branch of the Ministry of Health, Riyadh, SAU.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction The Saudi Ministry of Health implemented prescribing guidelines and an integrated Decision Support Tool within the electronic prescription system to enforce eligibility, quantity, and timing criteria for blood glucose monitoring devices. This study assessed guideline compliance, estimated potential cost savings, and modeled the potential expansion in patient coverage resulting from the rejection of non-compliant prescriptions. Methods This was a cross-sectional, descriptive study. Data were collected from the records of the electronic prescription system ("Wasfaty"), covering prescriptions for blood glucose monitoring devices issued between January and December 2023, both overall and by specific item. The data also included the number of prescriptions rejected due to non-compliance with guidelines, both in total and by item type, and the costs of the different blood glucose monitoring devices. Potential new patient coverage was modeled by dividing rejected items by the standard per-patient allocation over the prescribed interval. Results The Decision Support Tool rejected 1,600,517 non-compliant prescriptions for blood glucose monitoring devices, constituting 0.9% of the total prescriptions issued in 2023. Continuous glucose monitoring (CGM) system readers showed the highest non-compliance rate (64.6%), followed by glucometers (49.3%) and CGM system sensors (31.1%), while glucometer strips and lancets had minimal non-compliance rates (0.70% and 0.50%, respectively). The potential cost savings from rejecting non-compliant prescriptions totaled approximately USD 25.6 million (96 million Saudi Riyals). The greatest savings came from flash glucose monitoring system sensors (62.5%), followed by glucometer devices (14.6%), and glucometer strips (11.5%). The rejection of non-compliant prescriptions could enable expanded coverage of new patients, including 63,367 annually for glucometer strips, 56,399 for glucometer lancets, 212,529 for glucometers, 64,394 for glucose monitoring system sensors, and 28,025 for glucose monitoring system readers, based on standard prescription intervals. Conclusion Non-compliance was highest for CGM system readers, glucometers, and CGM system sensors. The rejection of non-compliant prescriptions through prescribing guidelines using the Decision Support Tool potentially leads to cost savings and expansion of blood glucose monitoring device coverage. Further research in Saudi Arabia is needed to identify factors influencing guideline adherence and to evaluate the intervention's impact on clinical outcomes.

Indexed as

blood glucose monitoring devicescost savingelectronic decision support toolirrational prescribingprescribing guidelinesprescription compliance