ArticleJournal of applied clinical medical physics2026
Determining optimal transit dosimetry gamma parameter values for the detection of failure modes using receiver operating curve analysis.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Determining optimal transit dosimetry gamma parameter values for the detection of failure modes using receiver operating curve analysis.Journal of applied clinical medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo determine the gamma criteria that maximize the sensitivity and specificity of the transit dosimetry software PerFRACTION (Sun Nuclear Corporation) under five possible failure modes in external beam radiotherapy.
methodsWe simulated five failure modes that potentially introduce large changes in the absorbed dose distribution: (1) Linac hardware incidents. In a VMAT head and neck treatment plan, erroneous plans were created, introducing known errors in the MLC aperture, the collimator angle, and the monitor units. (2) Breathing management protocol incidents. Based on a 4D-CT of a lung treatment, we created expiration and inspiration CT images. A treatment plan was created using each CT and recalculated in the alternate CT. (3) Patient identification incidents. The treatment plan of one breast patient was recalculated on another patient, and vice versa. (4) Selection of the planning CT incidents. A lung patient had two planning CTs with the presence/absence of lung fluid. A treatment plan was generated for each CT and recalculated for the other. (5) Bolus positioning incidents. An erroneous treatment plan for a breast plan was created without the bolus. For the five failure modes, the transit images were compared using seven gamma criteria, both global and local. Receiver-operating characteristic (ROC) curves were generated based on the change in the PTV mean dose: > 5%, > 10%, and > 20%. The area under the curve (AUC) and optimal passing rate were calculated.
resultsThe global gamma criterion γ(10%/1 mm) maximizes PerFRACTION sensitivity and specificity to detect failure modes that introduce a change in the PTV mean dose exceeding 10%. The standard global gamma criterion, as γ(3%/3 mm), maximizes PerFRACTION sensitivity and specificity to detect deviations in the PTV mean dose above 5%.
conclusionsA 10%, 1 mm global gamma parameter value produces the needed sensitivity and specificity to identify erroneous deliveries at a level of dose differences of 10% or greater.