Evidence map›Paper›PMID 41457940›Full record

ArticleJournal of applied clinical medical physics2026

Determining optimal transit dosimetry gamma parameter values for the detection of failure modes using receiver operating curve analysis.

David Sánchez-Artuñedo, Paula Navarro-Palomas, Marcelino Hermida-López, Maria Amor Duch-Guillén, Mercè Beltran-Vilagrasa

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

David Sánchez-ArtuñedoServei de Física i Protecció Radiològica, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.ORCID https://orcid.org/0000-0001-8323-4715
Paula Navarro-PalomasServei d'Oncologia Radioteràpica, Hospital Clínic de Barcelona, Barcelona, Spain.
Marcelino Hermida-LópezServei de Física i Protecció Radiològica, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.
Maria Amor Duch-GuillénUniversitat Politècnica de Catalunya, Institut de Tècniques Energètiques, Barcelona, Spain.
Mercè Beltran-VilagrasaServei de Física i Protecció Radiològica, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.

Funding

Spanish Society of Medical Physics
6 · The paper itself

Abstract

purposeTo determine the gamma criteria that maximize the sensitivity and specificity of the transit dosimetry software PerFRACTION (Sun Nuclear Corporation) under five possible failure modes in external beam radiotherapy.

methodsWe simulated five failure modes that potentially introduce large changes in the absorbed dose distribution: (1) Linac hardware incidents. In a VMAT head and neck treatment plan, erroneous plans were created, introducing known errors in the MLC aperture, the collimator angle, and the monitor units. (2) Breathing management protocol incidents. Based on a 4D-CT of a lung treatment, we created expiration and inspiration CT images. A treatment plan was created using each CT and recalculated in the alternate CT. (3) Patient identification incidents. The treatment plan of one breast patient was recalculated on another patient, and vice versa. (4) Selection of the planning CT incidents. A lung patient had two planning CTs with the presence/absence of lung fluid. A treatment plan was generated for each CT and recalculated for the other. (5) Bolus positioning incidents. An erroneous treatment plan for a breast plan was created without the bolus. For the five failure modes, the transit images were compared using seven gamma criteria, both global and local. Receiver-operating characteristic (ROC) curves were generated based on the change in the PTV mean dose: > 5%, > 10%, and > 20%. The area under the curve (AUC) and optimal passing rate were calculated.

resultsThe global gamma criterion γ(10%/1 mm) maximizes PerFRACTION sensitivity and specificity to detect failure modes that introduce a change in the PTV mean dose exceeding 10%. The standard global gamma criterion, as γ(3%/3 mm), maximizes PerFRACTION sensitivity and specificity to detect deviations in the PTV mean dose above 5%.

conclusionsA 10%, 1 mm global gamma parameter value produces the needed sensitivity and specificity to identify erroneous deliveries at a level of dose differences of 10% or greater.

Indexed as

Breast NeoplasmsHead and Neck NeoplasmsLung NeoplasmsRadiometryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAlgorithmsFemaleFour-Dimensional Computed TomographyGamma RaysHumansImage Processing, Computer-AssistedParticle AcceleratorsRadiotherapy DosageROC CurveSoftwarePerFRACTIONsensitivityspecificitytransit dosimetry

Identifiers

PMID41457940
PMCPMC12746048

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.