ArticleJournal of applied clinical medical physics2026

Commissioning and robustness evaluation of external laser sensor for respiratory gating in carbon-ion radiotherapy.

Tae-Ho Kim, Soorim Han, Dohyeon Yoo, Sangmin Lee, Taegeon Oh, Dongjoon Lee, Changhwan Kim, Min Cheol Han, Chae-Seon Hong, Jin Sung Kim

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Tae-Ho KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.ORCID https://orcid.org/0000-0001-5249-8451
Soorim HanDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
Dohyeon YooDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.ORCID https://orcid.org/0000-0002-1790-0297
Sangmin LeeDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
Taegeon OhDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Seoul, South Korea.
Dongjoon LeeDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Seoul, South Korea.
Changhwan KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.ORCID https://orcid.org/0000-0003-0050-0470
Min Cheol HanDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.ORCID https://orcid.org/0000-0002-1465-5636
Chae-Seon HongDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.ORCID https://orcid.org/0000-0001-9120-6132
Jin Sung KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRespiratory-induced tumor motion remains a significant challenge in carbon-ion radiotherapy (CIRT), potentially compromising dose accuracy and escalating dose in nearby organs. Although belt-based sensors are commonly used for gating, issues related to setup reproducibility and patient comfort increased the demand for laser-based, non-contact alternatives. PURPOSE: This study evaluates the performance of an ANZAI laser-based respiratory gating system for potential use in this modality based on total delay measurements and assessment of the accuracy and signal robustness of the sensor under a broad range of simulated and clinical conditions.

methodsThe total system delay was quantified through segmentation of the signal pathway into four steps: motion-to-waveform, waveform-to-gate, gate-to-beam, and signal-to-irradiation. A programmable motion phantom was used to assess the tracking accuracy under various conditions, including changes in amplitude, period, and irregular breathing patterns, such as baseline shifts and phase variations. Signal robustness was evaluated with varying the sensor-to-surface distance (9-17 cm), sensor angle (0-45°), ambient lighting, and interference from adjacent lasers. A volunteer study correlated the external laser signal with internal diaphragm motion obtained via four-dimensional computed tomography (4DCT) in supine and prone positions and assessed cross-compatibility with a belt-type sensor.

resultsThe total system delay was 59.3 ms for beam-on and 40.4 ms for beam-off, which is well below the 100-ms threshold. In the phantom tests, the sensor achieved precise tracking, with cross-correlation coefficients > 0.99 (regular and irregular respiratory patterns). The signal was robust across a 9-17 cm span and was stable in a dark environment. However, the measured amplitude increased at sensor angles > 20°, and considerable signal distortion occurred due to interference from an adjacent laser. A strong correlation between the sensor signal and internal organ motion was observed in volunteer tests in supine (r = 0.986) and prone (r = 0.961) positions. The interoperability with the belt sensor was excellent (r = 0.99).

conclusionsThe ANZAI laser sensor system is accurate and reliable, and it meets clinical latency requirements in respiratory-gated CIRT. It provides stable tracking under varied respiratory conditions. For optimal performance, maintaining a perpendicular sensor angle is recommended to ensure amplitude accuracy and mitigate crosstalk from adjacent lasers. These findings confirm the clinical readiness of the system and inform practical implementation.

Indexed as

Heavy Ion RadiotherapyLasersNeoplasmsPhantoms, ImagingRadiotherapy Planning, Computer-AssistedRespiratory-Gated Imaging TechniquesFour-Dimensional Computed TomographyHumansMovementRadiotherapy DosageRadiotherapy, Intensity-ModulatedRespirationANZAI laser sensorCIRTrespiratory‐gated radiotherapy

Identifiers

PMID41457857
PMCPMC12745880

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.