Evidence map›Paper›PMID 41457832›Full record

ArticleJournal of applied clinical medical physics2026

Dose optimization for CT scans of the temporal bone using spectral shaping tin filter.

Alexander von Hessling, Carlos Vinícius Gomes, Pia Niederau, Thiago Lima, Justus Roos, Natalia Saltybaeva

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alexander von HesslingDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.
Carlos Vinícius GomesDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.
Pia NiederauDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.
Thiago LimaDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.
Justus RoosDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.ORCID https://orcid.org/0000-0003-3122-6611
Natalia SaltybaevaDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.ORCID https://orcid.org/0009-0009-0831-4577

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputed tomography is a highly effective diagnostic tool for evaluating pathological conditions of the temporal bone. However, the relatively high radiation doses pose risks to radiosensitive organs, making dose optimization essential in accordance with the ALARA principle. Recent technological advances, such as tin-based photon-shaping filters, have enabled significant dose reduction in both dual- and single-energy CT without compromising image quality. PURPOSE: To evaluate the impact of a spectral shaping tin filter on image quality and radiation dose in temporal bone CT examinations.

methodsThirty-six patients undergoing temporal bone CT were retrospectively analysed. Group A (n = 13) underwent standard CT, while Group B (n = 23) underwent CT examination using 150 kVp beam with additional tin filtration. Images were reconstructed with model-based iterative reconstruction (ADMIRE, level 3) and assessed by two neuroradiologists using a 3-point Likert scale. Radiation dose was quantified via CTDIvol, DLP, and eye lens dose using Monte Carlo simulations.

resultsBoth protocols provided diagnostic-quality images. The protocol with tin filter achieved slightly superior image quality (median scores: overall 3.00 vs. 2.88, contrast 3.00 vs. 2.96, resolution 2.58 vs. 2.53; p < 0.05) with substantial inter-rater agreement (κ = 0.75-0.97). Mean CTDIvol and DLP decreased from 59.1 ± 12.1 mGy and 551.8 ± 226.8 mGy×cm (Group A) to 39.9 ± 1.7 mGy and 302.4 ± 33.8 mGy×cm (Group B) (p < 0.001). Eye lens dose was reduced by 34% (54.7 ± 10.9 mGy vs. 36.4 ± 2.2 mGy, p < 0.001).

conclusionsIncorporating a tin filter into temporal bone CT significantly reduces radiation exposure, including lens dose, without compromising-and in some cases slightly improving-image quality. Routine implementation of spectral shaping may enhance patient safety in clinical practice.

Indexed as

Image Processing, Computer-AssistedTemporal BoneTinTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedMonte Carlo MethodOrgans at RiskRadiation DosageRetrospective StudiesTinCTradiation dosetin filter

Identifiers

PMID41457832
PMCPMC12745887

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.