ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2026
Effect of Pulse Frequency on Shear-Induced Extension of Von Willebrand Factor in Continuous-Flow Ventricular Assist Device (CF-VAD).
Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- From biomimicry to clinical actionability: rethinking high-shear thrombosis as a mechanobiological system.Current opinion in hematology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Patients with continuous-flow ventricular assist devices (CF-VADs) face an elevated risk of nonsurgical bleeding. One hypothetical cause is that the loss of pulsatility promotes unraveling and enzymatic degradation of von Willebrand factor (VWF), a key clotting protein. Artificial pulsatility has been proposed to counter this effect, but the role of pulse frequency in VWF unraveling remains unclear. This study investigates VWF conformational changes in response to varying pulse frequencies. Membrane-bound VWF on human aortic endothelial cells (HAECs) exposed to pulsatile in vitro conditions exhibited significantly less unraveling than under continuous flow ( p < 0.005). To enable real-time observation of VWF conformation, VWF was immobilized in a microfluidic device and exposed to continuous or pulsatile flows (20, 40, or 60 pulses/min) to model HAEC-bound unraveling. Results showed that frequencies greater than or equal to 40 pulses/min significantly reduced maximum extension compared with continuous flow and low-frequency conditions (≤ 20 pulses/min), whereas minimum extension was greatest under continuous flow and declined as frequency increased. Step-change flow experiments revealed a time constant of 0.19 ± 0.04 seconds for extension and ~1 second for recoiling. These findings support optimizing pulsatile flow frequency as a strategy to minimize VWF unfolding and mitigate nonsurgical bleeding in CF-VAD patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.