Evidence map›Paper›PMID 41457171›Full record

ArticleCardiovascular and interventional radiology2026

Dual-Layer Spectral CT for in Vivo Thermometry During Thermal Ablation.

Nicole A Varble, Laetitia Saccenti, Christopher Favazza, Andrea Ferrero, Nathan Huber, Ivane Bakhutashvili, John W Karanian, Bradford J Wood, William F Pritchard

Abstract read
In one paragraph

Article in Cardiovascular and interventional radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. See the Heat: Turning Thermal Energy into Image with Spectral CT.Cardiovascular and interventional radiology · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Nicole A VarbleCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA. nicole.varble@nih.gov.ORCID http://orcid.org/0000-0003-2273-7962
Laetitia SaccentiCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.
Christopher FavazzaDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Andrea FerreroDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Nathan HuberPhilips Healthcare, Best, The Netherlands.
Ivane BakhutashviliCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.
John W KaranianCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.
Bradford J WoodCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.
William F PritchardCenter for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.

Funding

NIH Clinical Center NIH Z01 1ZID BC011242NIH Clinical Center NIH Z01 1ZID CL040015
6 · The paper itself

Abstract

purposeTo evaluate the ability of spectral CT to non-invasively monitor liver temperature in vivo during thermal ablation. MATERIALS AND

methodsUnder a protocol approved by the Institutional Animal Care and Use Committee, domestic swine (n = 3) underwent microwave ablation (MWA). Four thermocouples were percutaneously placed in the ablation region under ultrasound guidance. Single-probe MWA was performed for 5 min at 65W. Sequential dual-layer spectral CT scans were collected at 1-min intervals during and after ablation (n = 16 scans/subject). Pre- and post-ablation contrast-enhanced CTs were acquired. Virtual monoenergetic images (70 keV) were used to mask gas bubbles and metal artifacts and to identify and segment ROIs at the thermocouple tips. Electron density weighted (EDW), effective atomic number (Z-eff), and conventional CT results were associated with temperature using correlation analysis and polynomial curve fitting. Explanted ablation zones were sectioned perpendicular to the probe track, and gross pathology was analyzed.

resultsTwelve thermocouples were placed near the MWA probe shaft at a mean distance of 8.3 mm (range 2.5-24.0 mm). Maximum measurements for each thermocouple ranged from 46 to 99 °C (overall range 29-99 °C). Temperature measurements were compared to corresponding spectral CT imaging results (n = 192). At the thermocouple locations, the mean EDW was 103.9 ± 0.97 (range 98.5-105.8). A negative linear correlation was found between temperature and EDW (r = - 0.570, 95%CI [- 0.483 - 0.645], p < 0.001, root mean squared error = 8.05 °C).

conclusionThis proof-of-concept study demonstrated the feasibility of monitoring temperature in vivo using spectral CT during thermal ablation. Intraprocedural temperature feedback may improve treatment margin identification and monitoring of nearby critical structures.

Indexed as

Ablation TechniquesCatheter AblationLiverThermometryTomography, X-Ray ComputedAnimalsContrast MediaMicrowavesModels, AnimalSwineContrast MediaSpectral CTThermal ablationThermometry

Identifiers

PMID41457171
PMCPMC12963214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.