ArticleMedical & biological engineering & computing2026
EEGPARnet: time-frequency attention transformer encoder and GRU decoder for removal of ocular and muscular artifacts from EEG signals.
Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Effective Electroencephalogram (EEG) signal processing necessitates the mitigation of physiological artifacts. While deep learning frameworks have demonstrated superior performance over traditional methods for this task, their high complexity and computational demands hinder deployment on resource-constrained platforms. In this work, denoising network called EEGPARnet is proposed to address this limitation. The proposed architecture integrates transformer encoders equipped with temporal and spectral attention modules and a Gated Recurrent Unit (GRU)-based decoder. This fusion enables the model to learn time-frequency long-range similarities, facilitating efficient feature extraction and a reduced number of trainable parameters. Experimental validation of the proposed model on the EEGDenoiseNet dataset revealed an average temporal relative root mean square error ([Formula: see text]) of 0.289, spectral relative root mean square error ([Formula: see text]) of 0.312, and a correlation coefficient (CC) of 0.942 for ocular artifact removal. For muscular artifact removal, the proposed method achieved competitive results against state-of-the-art techniques, with mean [Formula: see text], [Formula: see text], and CC values of 0.458, 0.428, and 0.855, respectively. Compared to state-of-the-art model, the proposed EEGPARnet demonstrated a significant reductions in computational complexity with [Formula: see text] fewer trainable parameters, [Formula: see text] less FLOPS, and [Formula: see text] smaller storage, making it a step closer towards deployment on resource-constrained devices for real-time EEG denoising without compromising performance.
Indexed as
Identifiers
41456251What OpenQuestion holds
Registered trials