Evidence map›Paper›PMID 41452496›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026

Optimizing electrode spacing of a pentaspline pulsed field ablation catheter for high-precision 3D mapping.

Shu Yoshihara, Kazuyoshi Suenari, Yoshikazu Watanabe

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Shu YoshiharaDepartment of Clinical Engineering, Hiroshima City Hiroshima Citizens Hospital, Hiroshima, Japan.ORCID http://orcid.org/0009-0000-3022-2489
Kazuyoshi SuenariDepartment of Cardiology, Hiroshima City Hiroshima Citizens Hospital, 7-33 Motomachi, Naka-ku, Hiroshima City, Hiroshima, 730-8515, Japan. ksuenari@gmail.com.ORCID http://orcid.org/0000-0002-4867-1749
Yoshikazu WatanabeDepartment of Cardiology, Hiroshima City Hiroshima Citizens Hospital, 7-33 Motomachi, Naka-ku, Hiroshima City, Hiroshima, 730-8515, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulsed field ablation (PFA) is emerging as a nonthermal and myocardium-selective therapy for atrial fibrillation. Integration of the FARAWAVE™ catheter with the EnSite™ X three-dimensional electroanatomical mapping (3D-EAM) system remains in development, and the optimal display style, interelectrode spacing, and field scaling (FS) settings have not been established.

objectiveTo determine the optimal visualization configuration of the FARAWAVE™ catheter for achieving high geometric accuracy in 3D mapping.

methodsWe retrospectively analyzed 25 patients with atrial fibrillation who underwent PFA using the FARAWAVE™ pentaspline catheter visualized on the EnSite™ X system. Four configurations were tested: Medusa style (2.5 mm) and Garland styles (1-17-1 mm, 1-12-1 mm, and 1-11-1 mm). CT-derived left atrial anatomies were compared with electroanatomical reconstructions using ten concordance metrics (six distances and four angles). Accuracy was assessed with mean absolute error (MAE), Scale Score, Angle Score, and Shape Similarity.

resultsDistance-based MAE differed significantly among configurations (p < 0.05). The Garland 1-11-1 mm + FS setting achieved the lowest MAE (4.3-12.4 mm), while Garland 1-17-1 mm had the highest (8.5-28.4 mm). Scale Score also varied significantly (p < 0.001), whereas Angle Score and Shape Similarity were comparable across configurations.

conclusionThe Garland 1-11-1 mm configuration with Field Scaling provided the most accurate geometric concordance with CT anatomy. Optimized catheter display and FS correction can improve mapping fidelity and procedural safety in pulsed field ablation.

Indexed as

Atrial FibrillationBody Surface Potential MappingCatheter AblationImaging, Three-DimensionalSurgery, Computer-AssistedAgedElectrodesEquipment DesignEquipment Failure AnalysisFemaleHumansIrreversible Electroporation TherapyMaleMiddle AgedReproducibility of ResultsRetrospective StudiesAtrial fibrillationElectrode spacingField scalingPulsed field ablationThree-dimensional electroanatomical mapping

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.