ArticleArchives of orthopaedic and trauma surgery2025
Femoral stress distribution in fully hydroxyapatite-coated cementless versus polished cemented stems with identical geometry: a thermoelastic stress analysis.
Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionStress shielding and altered load transfer remain major concerns in total hip arthroplasty (THA). Stem fixation method and material properties strongly influence femoral stress distribution, but data directly comparing cementless and cemented stems of identical geometry are limited. MATERIALS AND
methodsSix fourth-generation composite femurs were used. Three were implanted with a fully hydroxyapatite-coated cementless stem, and three with a polished cemented stem. Mechanical loading of 100-1900 N at 5 Hz was applied to simulate single-leg stance. Thermoelastic stress analysis (TSA) was used to evaluate surface stress distribution across Gruen zones. Linear mixed models assessed differences between groups.
resultsBefore implantation, the highest stress was observed in the proximal femur. After implantation, stress shifted distally in both fixation methods. The cementless stem maintained higher compressive stress in the proximal-medial region compared with the cemented stem, which demonstrated a more uniform stress distribution between the medial and lateral cortices. TSA measurements confirmed significant proximal stress reduction with cemented fixation, while cementless fixation preserved proximal loading more effectively.
conclusionThis simulation study showed that fixation method and material influence short-term femoral stress distribution, even when stem geometry is identical. These findings describe only mechanical behavior under simplified conditions. The use of composite femurs, the one-size difference between stems, and the short-term evaluation limit the generalizability of the results. Further research using cadaveric models and clinical follow-up is required to clarify long-term remodeling and support stem selection in total hip arthroplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.