Evidence map›Paper›PMID 41452290›Full record

ArticleProsthetics and orthotics international2026

Evaluating modified socket casting and molding vs. total surface bearing techniques in unilateral transtibial amputation: Effects on rotational control, socket fit satisfaction, and interface pressure.

Batoul Bagheripour, Mohammad Ali Mardani, Behnam Hajiaghaei, Akbar Biglarian, Hamid Pezham, Taher Babaee

Abstract readComparative Study
In one paragraph

Article in Prosthetics and orthotics international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Batoul BagheripourDepartment of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.ORCID 0000-0002-6788-6104
Mohammad Ali MardaniDepartment of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
Behnam HajiaghaeiDepartment of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.
Akbar BiglarianDepartment of Biostatistics and Epidemiology, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
Hamid PezhamOrthotics and Prosthetics Unit, Department of Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.
Taher BabaeeDepartment of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo achieve functional and comfortable prostheses, great attention must be paid to socket design, as it represents a critical interface between the residual limb and the prosthetic limb. This study aimed to evaluate the outcomes of unilateral transtibial amputees utilizing modified socket casting/molding technique in comparison to total surface bearing (TSB) socket.

methodsEight individuals with unilateral transtibial amputation participated in this cross-over design trial. Each participant used both the TSB and modified socket casting/molding designs. Four weeks after the utilization of each socket, the assessment was conducted on socket fit satisfaction (measured through the Comprehensive Lower Limb Amputee Socket Survey), socket rotation (evaluated using a standard meter), socket/liner interface pressure (monitored with 10 force-sensitive resistors), and the amputees' decision regarding the retention of one of the sockets after the trials (gauged via a numerical rating scale).

resultsThe amputees experienced greater stability ( P = 0.02) and improved lateral rotational control ( P = 0.01) during prosthetic gait when using the modified socket, compared with the TSB socket. Local pressure on the anterodistal tibia and the head of the fibula was not statistically significant ( P > 0.05) between 2 socket types. The decision of participants to retain the modified socket was significantly higher than that for the TSB socket after the trial period ( P = 0.03).

conclusionThe modified socket design may offer advantages by providing improved rotational control during walking and reducing local pressure on the anterodistal tibia and fibula head. In addition, it maintains the total surface contact concept.

Indexed as

Amputation, SurgicalAmputeesArtificial LimbsPatient SatisfactionProsthesis DesignProsthesis FittingTibiaAdultCross-Over StudiesFemaleGaitHumansMaleMiddle AgedPressureRotationamputationpressureprosthesissatisfactionsocket fitstability

Identifiers

PMID41452290
PMCPMC13440531

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.