ArticleFrontiers in bioengineering and biotechnology2025

Finite element analysis of the biomechanical behavior of four osseointegrated prosthetic designs.

Zi-Xuan Guo, Zhen Wang, Xue-Lin Zhao, Cheng-Wei Cao, Zi-Fu Huang, Zhao-Hang Sun, Yu-Shu Zheng, Meng Xu

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zi-Xuan Guo *Department of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Zhen Wang *Department of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Xue-Lin ZhaoDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Cheng-Wei CaoDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Zi-Fu HuangDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Zhao-Hang SunDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Yu-Shu ZhengDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.
Meng XuDepartment of Orthopedics, The Forth Medical Center of PLA General Hospital, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Osseointegration is a critical determinant of the long-term stability and functional performance of orthopedic implants, with prosthetic morphology exerting substantial influence on biomechanical loading and bone-implant interface dynamics. This study aimed to evaluate the biomechanical behavior of four representative osseointegrated prosthetic designs using finite element analysis, to inform clinical application and guide optimization in prosthetic design. Methods: Three-dimensional finite element models were constructed to simulate host bone integrated with four distinct prosthetic configurations: (1) a threaded prosthesis representing the Osseointegrated Prostheses for the Rehabilitation of Amputees system, (2) a smooth press-fit prosthesis simulating the Osseointegrated Prosthetic Limb, (3) a titanium alloy prosthesis with a multi-porous surface, and (4) a molybdenum-rhenium (Mo-Re) alloy prosthesis with a multi-porous surface. Simulated physiological loading conditions were applied to evaluate stress distribution within prosthetic structures, interfacial mechanics at the bone-prosthesis junction, and stress transfer to surrounding osseous tissue. Results: All four prosthetic designs exhibited stress concentration at the distal stem region, with peak stress values ranging from 179 to 185 MPa, indicating comparable load-bearing characteristics. Incorporation of a multi-porous surface effectively reduced stress concentration on the inner cortical wall associated with groove geometry. The two multi-porous configurations demonstrated similar load transfer patterns, with maximum stress in adjacent bone tissue recorded at 20.4 MPa. The Mo-Re alloy prosthesis exhibited reduced deformation under equivalent loading due to its higher elastic modulus. Maximum stress within the porous section was 5.3 MPa for the Mo-Re prosthesis and 9.3 MPa for the titanium alloy variant, with no evidence of critical stress accumulation. Conclusion: The multi-porous Mo-Re alloy prosthesis demonstrated favorable mechanical compatibility through the optimized integration of material properties and structural design. Findings from the finite element analysis support its potential utility in osseointegrated orthopedic applications.

Indexed as

analysisbiomechanicalfinite elementosseointegrated prosthesisstress shielding

Identifiers

PMID41450776
PMCPMC12727996

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.