Evidence map›Paper›PMID 41449750›Full record

Observational studyMedical science monitor : international medical journal of experimental and clinical research2025

Incidence and Characteristics of Catheter-Related Thrombosis in Patients With Temporary Femoral Dialysis Catheters: A Prospective Observational Study.

İlkay Ceylan, Aytül Coşar Ertem, Ebru Karakoç, Hilmi Erdem Gözden, Erdinç Tanlak, Nermin Kelebek Girgin

Abstract readObservational Study
In one paragraph

Observational study in Medical science monitor : international medical journal of experimental and clinical research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

İlkay CeylanDepartment of Anesthesiology and Reanimation, TC SBU Bursa Yüksek İhtisas Training and Research Hospital, Bursa, Turkey.
Aytül Coşar ErtemDepartment of Intensive Care, TC SBU Bursa Yüksek İhtisas Teaching and Research Hospital, Bursa, Turkey.
Ebru KarakoçDepartment of Anesthesiology and Reanimation, Faculty of Medicine, TC Eskişehir Osmangazi University, Eskişehir, Turkey.
Hilmi Erdem GözdenDepartment of Haemotology, TC SBU Bursa Yüksek İhtisas Teaching and Research Hospital, Bursa, Turkey.
Erdinç TanlakDepartment of Radiology, Faculty of Medicine, TC Bursa Uludağ University, Bursa, Turkey.
Nermin Kelebek GirginDepartment of Anesthesiology and Reanimation, TC SBU Bursa City Training and Research Hospital, Bursa, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND According to recent guidelines, the femoral vein is the second-line option for dialysis catheter placement in patients undergoing acute extracorporeal treatments. This study aimed to determine the incidence of catheter-related thrombosis (CRT) in intensive care unit (ICU) patients with temporary femoral vein dialysis catheters and evaluate the effect of catheter diameter on thrombosis. MATERIAL AND METHODS This prospective observational study was conducted in a university hospital ICU. Temporary femoral dialysis catheters were inserted by anesthesia residents. Doppler ultrasonography (DUSG) examinations were performed at 24 and 48 h and on days 7 through 10 after catheter placement, assessing the venous segment from the insertion site or inguinal ligament to the popliteal vein. Examinations were conducted by an intensivist and reviewed by a radiologist. Thrombosis and femoral vein diameters were recorded, along with demographic and laboratory data. RESULTS Among 262 ICU admissions during the study period, 37 patients who received temporary femoral dialysis catheters were included. CRT was detected in 7 patients (18.9%). In 5 cases, thrombosis occurred between days 7 and 10 post-insertion; in 2 cases, it was identified after catheter removal. All events were asymptomatic; no catheter dysfunction was observed. There were no significant differences between patients with and without thrombosis regarding body mass index, smoking status, mortality, or severity scores. CONCLUSIONS The incidence of asymptomatic CRT was 18.9% in ICU patients with femoral dialysis catheters. Routine DUSG may facilitate early detection of thrombosis, allowing timely intervention and potentially reducing the risk of thromboembolic events and catheter-related complications.

Indexed as

Femoral VeinRenal DialysisThrombosisAdultAgedFemaleHumansIncidenceIntensive Care UnitsMaleMiddle AgedProspective Studies