Evidence map›Paper›PMID 41448770›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2025

[Numerical analysis research on the impact of tibial tray fixation peg structure on initial fixation stability in total knee arthroplasty].

Yuanxu Ling, Jianian Han, Zhifeng Zhang, Yinghu Peng, Jing Zhang, Zhenxian Chen, Zhongmin Jin

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuanxu LingSchool of Mechanical Engineering, Chang'an University, Xi'an 710064, P. R. China.
Jianian HanSchool of Mechanical Engineering, Chang'an University, Xi'an 710064, P. R. China.
Zhifeng ZhangDepartment of Joint Surgery, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010110, P. R. China.
Yinghu PengShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518000, P. R. China.
Jing ZhangSchool of Mechanical Engineering, Chang'an University, Xi'an 710064, P. R. China.
Zhenxian ChenSchool of Mechanical Engineering, Chang'an University, Xi'an 710064, P. R. China.
Zhongmin JinTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to investigate the impact of tibial tray fixation peg structure in posterior stabilized (PS) knee prostheses on its initial fixation stability, a finite element model and a micromotion prediction model of PS total knee arthroplasty (TKA) were established to comparatively study the differences in the von Mises stress of the proximal tibia and the micromotion at the bone-prosthesis fixation interface under four PS tibial tray fixation peg design, namely cylindrical plus hemispherical, cylindrical plus conical, hexagonal prism, and cruciform. The results showed that, at the moment of the maximum force of knee joint during level walking activity, there was no significant difference in the tibial von Mises stress between the tibial tray with or without fixation peg designs. However, the peak micromotions at the prosthesis fixation interface of all tibial trays with fixation peg design were significantly reduced. Among them, the micromotion suppression effect of the cruciform fixation peg was the most obvious. At the moment of the maximum flexion angle of knee joint during squatting activity, the tibial von Mises stress for tibial trays with fixation peg design was clearly lower than that without fixation peg design, meanwhile the peak micromotion at the prosthesis fixation interface was also significantly reduced. Overall, the cruciform fixation peg design showed the best fixation stability and effectively reduced the loosening risk at the prosthesis fixation interface. This study recommended that the backside of the tibial tray in non-cemented PS knee prostheses adopted a design combining a cylindrical stem with a serrated keel and a cruciform fixation peg. This study provided an important reference basis for improving the initial fixation stability of non-cemented PS knee prostheses by optimizing the backside design of the tibial tray.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis DesignTibiaBiomechanical PhenomenaFinite Element AnalysisHumansKnee JointStress, MechanicalFixation peg designMicromotionPosterior-stabilized knee prosthesisTibial trayTotal knee arthroplastyVon Mises stress

Identifiers

PMID41448770
PMCPMC12744981

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked