ArticleBMJ open2025
Retrospective validation of an artificial intelligence system for diagnostic assessment of prostate biopsies on the ProMort cohort: study protocol.
Article in BMJ open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Artificial intelligence in small tissue biopsies: diagnostic applications, histochemical integration, and methodological challenges in surgical pathology.Histochemistry and cell biology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionProstate cancer diagnosis and treatment planning depend on accurate histopathological assessment of needle biopsies, particularly through the Gleason scoring system. The inherently subjective nature of the grading creates variability between pathologists, potentially resulting in suboptimal patient management decisions. These reproducibility challenges extend beyond Gleason scoring to encompass other critical diagnostic and prognostic markers, including cancer volume quantification and detection of cribriform morphology patterns and perineural invasion. Artificial intelligence (AI) applications in digital pathology have emerged as promising solutions for enhancing diagnostic consistency and accuracy, with recent research demonstrating that automated systems can match expert-level performance in prostate biopsy evaluation. Nevertheless, comprehensive validation studies have revealed concerning limitations in model generalisability when deployed across different clinical environments and patient populations. Recent systematic reviews revealed widespread risk-of-bias limitations and insufficient external validation in AI diagnostic studies, highlighting critical needs for accumulated evidence supporting generalisability before clinical implementation. Rigorous external validation with preregistered protocols using independent datasets from diverse clinical settings remains essential to establish the reliability and safety of AI-assisted prostate pathology systems. METHODS AND ANALYSIS: This study protocol establishes a framework for the retrospective external validation of an AI system developed for prostate biopsy assessment, to be conducted on the case-control samples of the National Prostate Cancer Register of Sweden, ProMort study (1998-2015). The primary aim is to evaluate the AI model's diagnostic accuracy and Gleason grading performance using completely independent datasets separate from any model development or previously used validation cohorts. The diversity of the validation samples, spanning multiple geographic regions, temporal collection periods and reference standards, allows evaluation of model robustness across varied clinical contexts. Secondary aims encompass evaluating AI performance in cancer length estimation and detection of cribriform patterns and perineural invasion. This protocol delineates procedures for data collection, reference standard clarification and prespecified statistical analyses, ensuring comprehensive validation and reliable performance assessment. The study design conforms to established reporting guidelines Checklist for Artificial Intelligence in Medical Imaging (CLAIM) and Standards for Reporting Diagnostic Accuracy Studies using Artificial Intelligence (STARD-AI), and recognised best practices for AI validation in medical imaging. ETHICS AND DISSEMINATION: Data collection and usage were approved by the Swedish Regional Ethics Review Board and the Swedish Ethical Review Authority (permits 2012/1586-31/1, 2016/613-31/2, 2019-01395, 2019-05220). The study adheres to the Declaration of Helsinki principles, and findings will be made available in open access peer-reviewed publications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.