Clinical Experience With Nasogastric Tube Placement Using a Biologically Transparent Illumination System in Critically Ill Patients.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Usefulness of Transparent Illumination Device in Esophageal Atresia for the Detection of the Distal Esophagus.Surgical case reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A biologically transparent illumination (BTI) system has been proposed as an adjunctive method for confirming nasogastric tube (NGT) placement by visualizing a light in the stomach. However, its clinical applicability in critically ill patients remains unclear. We conducted a preliminary prospective observational study to evaluate the clinical feasibility and detectability of a BTI system for NGT placement in critically ill patients. Ten critically ill patients underwent NGT placement using a BTI system after admission to the intensive care unit (ICU). The detected BTI light was assessed in the epigastric region, and the NGT tip was subsequently confirmed using X-ray. The BTI light was visible in five patients, while X-ray confirmed stomach placement in all. Notably, in patients with obesity, massive ascites, or a considerable distance between the NGT tip and the skin surface, the BTI system did not detect the light. No complications during the procedure were reported. This early clinical experience indicates that although BTI detectability is limited by patient-specific anatomical factors, the system may serve as a supportive, hypothesis-generating approach for bedside confirmation of NGT placement in critically ill patients. Further studies are needed to identify the patient groups that benefit most from the BTI system.