Evidence map›Paper›PMID 41441392›Full record

ArticleTomography (Ann Arbor, Mich.)2025

Pilot Evaluation of a Deep Learning Model for Nasogastric Tube Verification on Chest Radiographs: A Single-Center Retrospective Study.

Sang Won Park, Doohee Lee, Jae Eun Song, Yoon Kim, Hyun-Soo Choi, Seung-Joon Lee, Woo Jin Kim, Kyoung Min Moon, Oh Beom Kwon

Abstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sang Won ParkDepartment of Next Generation Information Center, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.ORCID 0000-0001-9796-2799
Doohee LeeDepartment of Research and Development, ZIOVISION Co., Ltd., Chuncheon 24341, Republic of Korea.ORCID 0000-0002-5838-6925
Jae Eun SongDepartment of Radiology, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.
Yoon KimDepartment of Research and Development, ZIOVISION Co., Ltd., Chuncheon 24341, Republic of Korea.ORCID 0000-0001-5709-5766
Hyun-Soo ChoiDepartment of Research and Development, ZIOVISION Co., Ltd., Chuncheon 24341, Republic of Korea.ORCID 0000-0002-3594-8948
Seung-Joon LeeDivision of Pulmonology, Department of Internal Medicine, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.ORCID 0000-0003-4597-0281
Woo Jin KimDivision of Pulmonology, Department of Internal Medicine, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.ORCID 0000-0003-2927-370X
Kyoung Min MoonDivision of Pulmonary and Allergy Medicine, Department of Internal Medicine, Chung-Ang University Hospital, Seoul 06973, Republic of Korea.
Oh Beom KwonDivision of Pulmonology, Department of Internal Medicine, Kangwon National University Hospital, Chuncheon 24289, Republic of Korea.ORCID 0000-0003-0084-2657

Funding

Ministry of Science and ICT Korea Technology R&D Project through the National IT Industry Promotion Agency (NIPA) and Gangwon Information and Culture Industry Promotion Agency (GICA)
6 · The paper itself

Abstract

backgroundAccurate confirmation of nasogastric (NG) tubes is essential for patient safety, but delays and variability in interpretation remain common in clinical practice. Deep learning (DL) models have shown potential for assisting in this task, but real-world performance, particularly in detecting malpositioned tubes, remains insufficiently characterized.

methodsWe conducted a pilot evaluation of a previously developed DL model using 135 chest radiographs from Kangwon National University Hospital. Expert physicians established the reference standard. Model performance was assessed and receiver operating characteristic (ROC) curve and precision recall curve (PRC) analyses were performed. Differences between correctly classified and misclassified cases were examined using Wilcoxon rank-sum and Fisher's exact tests to explore potential clinical or radiographic contributors to model failure.

resultsThe model correctly classified 129 of 135 cases. The sensitivity was 96.1% (95% confidence interval (CI): 92.2-98.9%), specificity was 85.7% (95% CI: 42.2-97.7%), positive predictive value (PPV) was 99.2% (95% CI: 96.1-99.9%), negative predictive value (NPV) was 54.5% (95% CI: 25.4-80.8%), balanced accuracy was 90.8%, and F1-score was 0.976. The area under the ROC curve was 0.970 (95% CI: 0.929-1.000) and that under the PRC was 0.727 (95% CI: 0.289-1.000), reflecting substantial uncertainty related to the very small number of incomplete cases (

conclusionsThe DL model performed well in identifying correctly positioned NG tubes but demonstrated limited and unstable performance for detecting incomplete placements. Given the safety implications of misclassification, the model should be used only as an assistive tool with mandatory physician oversight. Larger, multi-center studies with greater representation of incomplete cases are required to obtain more reliable estimates and support safe clinical implementation.

Indexed as

Deep LearningIntubation, GastrointestinalRadiography, ThoracicAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedPilot ProjectsPredictive Value of TestsRetrospective StudiesROC CurveSensitivity and Specificitydeep learning modelnasogastric tubereal-world validation

Identifiers

PMID41441392
PMCPMC12737375

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.