Evidence map›Paper›PMID 41437086›Full record

ArticleJournal of orthopaedic surgery and research2025

Biomechanical analysis of anatomical intramedullary nails and proximal femoral anti-rotation-II intramedullary nails for the treatment of unstable intertrochanteric fractures (AO type 31-A2.2) in older patients.

Xian-Wen Ma, Jian Chen, Yong Hu, Zheng-Rui Fan

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xian-Wen MaDepartment of Orthopedics, The First Affiliated Hospital of Anhui Medical University, Hefei, 230022, People's Republic of China.
Jian Chen2. Department of Orthopedics, Tianjin Hospital, Tianjin, 300050, People's Republic of China.
Yong HuDepartment of Orthopedics, The First Affiliated Hospital of Anhui Medical University, Hefei, 230022, People's Republic of China. AnhuiGKHY@163.com.
Zheng-Rui Fan2. Department of Orthopedics, Tianjin Hospital, Tianjin, 300050, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo explore the biomechanical properties of Zimmer natural nail (ZNN) and proximal femoral nail antirotation (PFNA)-II nails in treating older patients with unstable intertrochanteric fractures, thereby guiding the selection of internal fixation devices in clinical practice.

methodZNN and PFNA fixation models for unstable intertrochanteric fractures (AO type 31-A2.2) were established using the three-dimensional finite element method and in vitro mechanical experiments, respectively. We compared the Von Mises stress distribution, peak stress, implants and femur locations, displacement distribution, maximum displacement, location of the models, and maximum crack distance at the fracture ends between the two groups. Additionally, we compared the axial stiffness, femoral head axial displacement, and failure load for both groups.

resultFinite element analysis for AO type 31-A2.2 unstable intertrochanteric fractures showed that stresses in the ZNN and PFNA-II models concentrated at the distal locking screws, with maximum Von Mises stresses of 373.2 MPa and 811.5 MPa, respectively. The femoral stress concentrated at the distal locking screw perforation hole, with maximum Von Mises stresses of 186.5 MPa for ZNN and 1602.0 MPa for PFNA-II. According to the displacement distribution cloud map, the maximum displacements of the ZNN and PFNA-II models were 3.768 mm and 3.757 mm, respectively, both at the top of the femoral head. The maximum crack distances in the ZNN and PFNA-II models were 0.16 mm and 0.14 mm, respectively. The maximum displacements and crack distances at the fracture end were similar for both models. Biomechanical tests revealed that the axial stiffness in the ZNN group was greater than that in the PFNA-II group, with averages of 299.67 ± 27.00 N/mm and 269. 6 ± 15. 24 N/mm, respectively; the difference between the two groups was significant (T = 2. 375, P = 0. 039). In the cyclic loading test, the average axial displacement of the femoral head was 0.62 ± 0.22 mm in the ZNN group and 0.59 ± 0.23 mm in the PFNA-II group, with no significant differences (t = 0. 155, P = 0. 880). The failure load of the ZNN group significantly exceeded that of the PFNA-II group, with average failure loads of 3.95 ± 0.07 kN and 3.54 ± 0. 15 kN, respectively (t = 6.207, P < 0.001).

conclusionIn AO type 31-A2.2 unstable intertrochanteric fractures, the biomechanical properties of the ZNN group were superior to those of the PFNA-II group in terms of axial stiffness and failure load. In the cyclic loading test, the axial displacement of the femoral head was similar in both groups. The finite element analysis showed a more favorable mechanical distribution for the ZNN group. The ZNN implant demonstrated favorable biomechanical characteristics under the specific experimental conditions tested in this study.

Indexed as

Bone NailsFracture Fixation, IntramedullaryHip FracturesAgedAged, 80 and overBiomechanical PhenomenaFinite Element AnalysisHumansMaleRotationStress, MechanicalInternal fixation within fracture lineIntertrochanteric femoral fracture

Identifiers

PMID41437086
PMCPMC12836932

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.