Evidence map›Paper›PMID 41431606›Full record

ArticleSurgical case reports2025

Bladder Herniation through the Obturator Foramen Treated with Laparoscopic Transabdominal Preperitoneal Repair Using a Contralateral 3D Max Mesh: A Case Report.

Ryozan Naito, Keisuke Ieta, Momoka Arai, Shigeo Maki, Katsuya Osone, Masaki Suzuki, Yohei Miyamae, Keitaro Hirai, Ichiro Sakamoto, Hiroshi Saeki

Abstract readCase Reports
In one paragraph

Article in Surgical case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ryozan NaitoDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Keisuke IetaDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Momoka AraiDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Shigeo MakiDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Katsuya OsoneDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Masaki SuzukiDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Yohei MiyamaeDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Keitaro HiraiDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Ichiro SakamotoDepartment of Surgery, Takasaki General Medical Center, Takasaki, Gunma, Japan.
Hiroshi SaekiDepartment of General Surgical Science, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionObturator hernia is an uncommon condition. With the widespread adoption of laparoscopic surgery, incidental detection of obturator hernias has become increasingly frequent. Bladder herniation through the obturator foramen is extremely rare, with only 14 cases reported to date. Herein, we describe a rare case of obturator bladder hernia successfully repaired via the laparoscopic transabdominal preperitoneal (TAPP) approach, highlighting a novel technical modification. CASE PRESENTATION: A 74-year-old female was diagnosed with an obturator bladder hernia. The patient initially presented to the hospital with hematochezia and was diagnosed with ischemic colitis. Initial CT revealed an obturator hernia in the small intestine. The following day, CT revealed an obturator bladder hernia, although she had no symptoms related to an obturator bladder hernia. Subsequent CT at our hospital established a diagnosis of obturator bladder hernia. The patient underwent laparoscopic obturator hernia repair via the TAPP approach. A contralateral 3D MAX MID Anatomical Mesh (Bard; Warwick, RI, US) was deployed. The mesh was rotated 180° around its medial axis and positioned with the convex surface facing the abdominal wall to achieve an optimal anatomical fit. The operative time was 148 minutes, with an estimated blood loss of 10 mL. The postoperative course was uneventful, and the patient was discharged on the 3rd POD.

conclusionsCurrently, there is no clear consensus regarding the surgical indications for obturator bladder hernia. In the present case, although the patient was asymptomatic, daily changes in hernia contents raised concerns regarding potential small bowel incarceration, prompting surgical intervention. Our novel modification of the TAPP approach involved the placement of a contralateral 3D MAX mesh rotated 180° around its medial axis. This adjustment preserved the anatomical curvature of the mesh, facilitated secure fixation, and ensured adequate coverage of the obturator foramen and femoral ring.

Indexed as

bladder herniaobturator herniatransabdominal preperitoneal (TAPP)

Identifiers

PMID41431606
PMCPMC12719013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.