Evidence map›Paper›PMID 41430582›Full record

ArticleBMC geriatrics2025

Comparing the digital dynamometer and Martin vigorimeter for handgrip strength: reliability, agreement, and prognostic value.

Shuyue Luo, Xiaoyan Chen, Rongna Lian, Huiyu Tang, Zecong Chen, Wenhua Jiang, Jiaojiao Jiang, Ming Yang

Abstract readComparative StudyMulticenter Study
In one paragraph

Article in BMC geriatrics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shuyue Luo *Center of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China.
Xiaoyan Chen *Center of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China.
Rongna LianCenter of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China.
Huiyu TangCenter of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China.
Zecong ChenDepartment of Geriatric, Zigong Affiliated Hospital of Southwest Medical University, Zigong, China.
Wenhua JiangCenter of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China.
Jiaojiao JiangRehabilitation Center, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China. jiangjiaojiao1997@163.com.
Ming YangCenter of Gerontology and Geriatrics, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Chengdu, China. yangmier@gmail.com.

Funding

Sichuan Provincial Department of Science and Technology 2024JDKP0099the Health and Family Planning Commission of Sichuan Province ZH2023-103
6 · The paper itself

Abstract

backgroundHandgrip strength (HGS) measurement is vital for clinical assessment in older adults, yet comparative performance of different devices in Asian populations remains understudied. Prior validation focused mainly on healthy adults, but this is the first comprehensive comparison in institutionalized older adults with cognitive impairment and ADL disability. To compare the measurement properties and prognostic value of a digital dynamometer and Martin vigorimeter in Chinese nursing home residents, especially those with ADL disability and cognitive impairment.

methodsA multicenter longitudinal study of 772 residents (502 men, 270 women; median age 71.0 vs. 80.5 years) from 15 nursing homes. HGS was measured with both devices per standardized protocols. Test-retest and inter-rater reliability were evaluated using ICC, CV, SEM, MDC, and Spearman’s ρ. Device agreement was assessed via Bland-Altman, and prognostic value for 30-month mortality was analyzed with Cox regression, adjusting for multiple covariates.

resultsBoth devices showed excellent test-retest reliability (digital ICC: 0.945; Martin ICC: 0.943). The Martin vigorimeter performed better in participants with ADL disability (CV: 10.48% vs. 14.01%; SEM: 8.6% vs. 11.6%; MDC: 23.0% vs. 25.7%). Inter-rater reliability favored the Martin device (ICC: 0.790 vs. 0.664). Strong correlations were observed (R = 0.60–0.62). Both devices had comparable prognostic value for mortality (adjusted HR: digital 4.50; Martin 2.77), despite different measurement principles.

conclusionsBoth devices are reliable mortality predictors in older adults, but the Martin vigorimeter offers superior properties in those with ADL disability. These findings inform device selection for vulnerable older populations.

Indexed as

Geriatric AssessmentHand StrengthMuscle Strength DynamometerActivities of Daily LivingAgedAged, 80 and overFemaleHumansLongitudinal StudiesMaleNursing Home ResidentsPrognosisReproducibility of ResultsDigital dynamometerHandgrip strengthMartin vigorimeterMortalityOlder adultsReliability

Identifiers

PMID41430582
PMCPMC12836778

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.