Evidence map›Paper›PMID 41430165›Full record

ArticleBMC musculoskeletal disorders2025

Augmented reality-based portable navigation improves accuracy of cup placement in total hip arthroplasty with a short learning curve.

Tetsuya Tachibana, Hiroki Katagiri, Takahisa Ogawa, Ryusuke Saito, Tetsuya Jinno

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tetsuya TachibanaDepartment of Orthopedic Surgery, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya City, Saitama, Japan.
Hiroki KatagiriDepartment of Orthopedic Surgery, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya City, Saitama, Japan. hirokik@dokkyomed.ac.jp.
Takahisa OgawaDepartment of Health Policy and Informatics, Graduate School of Institute of Science Tokyo, Institute of Science Tokyo, Tokyo, Japan.
Ryusuke SaitoDepartment of Orthopedic Surgery, Saitama Red Cross Hospital, Saitama, Japan.
Tetsuya JinnoDepartment of Orthopedic Surgery, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya City, Saitama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMalpositioning of the acetabular cup in total hip arthroplasty (THA) can cause complications including dislocation, wear, and aseptic loosening. Although computed tomography (CT)-based navigation systems have improved THA accuracy, the high cost and complexity of these systems have hindered their widespread use. Therefore, this study investigated the accuracy and learning curve of an augmented reality (AR)-based portable navigation system.

methodsThis retrospective study analyzed 106 hips in 87 patients who underwent primary THA using an AR-based portable navigation system between July 2023 and December 2024. A single surgeon performed all surgeries. The accuracy of the intraoperative navigation records for cup inclination and anteversion was assessed by comparing them with postoperative CT-based measurements. Absolute error values exceeding 5° and 10° were defined as outliers > 5° and > 10°, respectively. Receiver operating characteristic (ROC) analysis was used to evaluate the learning curve, and multivariate logistic regression identified risk factors associated with cases classified as outliers (> 5°).

resultsThe mean absolute errors between the navigation records and postoperative measurements were 2.2° for inclination and 3.8° for anteversion. Outliers > 5° were observed in 31% of cases, while outliers > 10° were rare (2.8%). No dislocations or revisions occurred within six months. Learning curve analysis showed consistent accuracy in the initial cases. The only significant predictor of navigation error was intraoperative posterior pelvic tilt change (odds ratio 1.13, p = 0.04). Body mass index and subcutaneous fat thickness were not significantly different.

conclusionsThe AR-based portable navigation provided highly accurate acetabular cup placement without a learning curve. However, excessive intraoperative posterior pelvic tilt increased the risk of anteversion overestimation, highlighting the need for intraoperative pelvic position management.

Indexed as

Arthroplasty, Replacement, HipAugmented RealityLearning CurveSurgery, Computer-AssistedAcetabulumAgedFemaleHip ProsthesisHumansMaleMiddle AgedRetrospective StudiesSurgical Navigation SystemsTomography, X-Ray ComputedAugmented realityCup positionLearning curvePortable navigationTotal hip arthroplasty

Identifiers

PMID41430165
PMCPMC12750653

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.