ArticleMikrochimica acta2025
Low-power microfluidic RT-LAMP system with real-time fluorescence detection for portable nucleic acid testing.
Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
A microfluidic reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform is presented featuring integrated real-time fluorescence detection and optimized thermal control. Magnetic bead-based RNA extraction was paired with a thermally insulated reaction chip operated under vacuum to suppress heat loss. Additional energy-saving strategies, including reduced wire cross-section and low-emissivity surface treatment, reduced total power consumption from (2.00 ± 0.08) W to (0.29 ± 0.01) W, corresponding to an 85.5 % reduction. Amplification was completed within 20 min, and positive fluorescence signals were detected in less than 11 min. Although LAMP reagents remain more expensive than those used in PCR, the substantial energy savings and system simplification demonstrated here support practical battery-powered operation. The RT-LAMP chemistry used in this system matched a previously validated configuration, which achieved a limit of detection of 256 RNA copies and a signal slope of (- 1.70 ± 0.20) dec.min⁻
Indexed as
Identifiers
41428227What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.