Preliminary evaluation of image quality in supine breast MRI using a dedicated wearable coil and accelerometer-based motion correction.
Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05218460 (Evaluation of Methodological and Technical DEvelopmeNts to Improve the Quality and Comfort of Magnetic Resonance Imaging Exam on Voluntary Subjects), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation of Methodological and Technical DEvelopmeNts to Improve the Quality and Comfort of Magnetic Resonance Imaging Exam on Voluntary Subjects
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Supine breast MRI offers easier comparison with other screening methods than the prone MRI, but is often impaired by respiratory artifacts. This study aims to identify a suitable acceleration technique for motion-corrected supine breast MRI with a dedicated wearable coil (BraCoil), and to assess the quality of the resulting images. This prospective, single-center study included ten healthy female volunteers. Supine breast MRI was acquired using the BraCoil equipped with seven accelerometers. The acquisition protocol included unenhanced T1- and T2-weighted sequences; 2-, 3-, and 4-fold acceleration, as well as "elliptical scanning", were tested for T1-weighted images. Image reconstruction was performed using two methods: the manufacturer's standard algorithm and an advanced nonrigid motion correction algorithm. The images were compared to each other and to conventional prone MRI via radiological scoring. Additionally, comparisons were made with supine breast MRI obtained using a multi-purpose torso coil reported in previous studies. This study showed that using 2-fold acceleration was optimal for motion-corrected supine breast MRI using the BraCoil. It also demonstrated that enabling the "elliptical scanning" would shorten the measurement time by 33% without compromising image quality. Finally, for the data acquired, the BraCoil provides superior motion-corrected image quality compared to the torso coil. KEY POINTS: BraCoil image quality outperforms the body coil for both uncorrected and motion-corrected images in supine acquisition for T1w and T2w sequences. Enabling the "elliptical scanning" in T1-weighted sequences does not impair image quality while shortening the measurement time by 33% (compared to the same sequence without enabling this option). A 2-fold acceleration for the T1-weighted sequence provides sufficient scan time reduction, whereas higher acceleration would lead to even shorter scan time at the cost of significantly lower image quality.