Evidence map›Paper›PMID 41427671›Full record

ArticleJournal of synchrotron radiation2026

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation.

Piotr Maj, Grzegorz W Deptuch, Dominik S Gorni, Giovanni Pinaroli, Gabriella A Carini, David P Siddons, Ryan Tappero, Soumyajit Mandal, Donald Pinelli, Timothy Kersten and 3 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Piotr MajInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0002-1059-6376
Grzegorz W DeptuchInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0003-1703-6758
Dominik S GorniInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0001-9613-7180
Giovanni PinaroliInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0001-6739-0339
Gabriella A CariniInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.
David P SiddonsNSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0003-1482-9867
Ryan TapperoNSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0002-3560-2461
Soumyajit MandalInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0001-9070-2337
Donald PinelliInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0009-0005-7090-3613
Timothy KerstenInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0009-0003-4217-5503
Nicholas St JohnInstrumentation Department, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0002-8758-1877
Abdul K RumaizNSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.ORCID 0000-0002-9907-299X
Anthony KuczewskiNSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000, USA.

Funding

Brookhaven Science Associates LLC DE-SC0012704
6 · The paper itself

Abstract

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

Indexed as

energy spectroscopyevent-driven readoutfluorescence imagingfront-end electronicslow-noise measurementspixel detectorsparse datasynchrotron radiation

Identifiers

PMID41427671
PMCPMC12809457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.