Evidence map›Paper›PMID 41427533›Full record

ArticleInternational journal of surgery (London, England)2025

Optimisation strategies for intramedullary nailing parameters in subtrochanteric fractures of the femur: a multimodal assessment based on finite element and biomechanical experiments.

Xiangyu Qi, Chao Li, Jiawen Wang, Qing Zhang, Xu Zhang, Yazhong Zhang, Yongxiang Lv, Wenbo Li, Ziqiang Zhu

Abstract read
In one paragraph

Article in International journal of surgery (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xiangyu QiDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Chao LiDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Jiawen WangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Qing ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Xu ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Yazhong ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Yongxiang LvDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Wenbo LiDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Ziqiang ZhuDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSubtrochanteric femur fractures account for 40 % of proximal femur fractures, and intramedullary nailing (IMN) is the treatment of choice, but there is a lack of uniformity in the selection of models. The challenge of individualized adaptation of diameter and length needs to be resolved, as too large or too small may lead to a lack of stability or increased surgical risk.

objectiveTo establish a parametric selection model by analyzing the biomechanical properties of IMNs of different specifications to provide a basis for the clinical optimization of implantation strategies.

methodsFinite element analysis combined with in vitro biomechanical experiments was used to construct a three-dimensional model based on femur CT data from healthy volunteers to assess the stress distribution and displacement characteristics of 15 sets of IMN (10/11/12 mm in diameter and 280-360 mm in length); a Sawbone artificial bone was used to simulate the Seinsheimer II C fracture, and the strain under axial compression was tested, ultimate load and failure mode.

resultThe 12 mm diameter IMN performed optimally biomechanically, with lower displacement and stress peaks than the smaller diameter group, but may exacerbate the femoral neck stress masking effect. Nail length had no significant effect on stress. Re-fracture around the locking screws occurred in all groups at a load of 5 kN, suggesting a mechanically weak zone near the fracture line.

conclusionFor patients with Seinsheimer type IIC subtrochanteric femoral fractures who have good bone quality and a femoral neck anteversion angle ≤15°, this study proposes a personalized selection strategy using CT-based 3D reconstruction of the narrowest medullary cavity diameter, recommending an anatomically matched intramedullary nail (320 mm length) to optimize both mechanical stability and biological healing. The results provide important theoretical support for clinical precision treatment.

Indexed as

finite element analysissubtrochanteric femoral fracturevitro biomechanical experiments

Identifiers

PMID41427533
PMCPMC13105675

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.