Evidence map›Paper›PMID 41427069›Full record

ArticleSovremennye tekhnologii v meditsine2025

Development of L1 Vertebral Anthropomorphic Model for Densitometric Phantom Improvement.

A V Petraikin, A M Mikhailova, N D Kudryavtsev, M V Cherkasskaya, V O Yastrebova, O V Omelyanskaya, Y A Vasilev

Abstract read
In one paragraph

Article in Sovremennye tekhnologii v meditsine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

A V PetraikinMD, DSc, Associate Professor, Senior Researcher, Standardization and Quality Control Department; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
A M MikhailovaJunior Researcher, Innovative Technologies Department; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
N D KudryavtsevJunior Researcher, Standardization and Quality Control Department; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
M V CherkasskayaPhD, Researcher, Standardization and Quality Control Department; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
V O YastrebovaJunior Researcher, Standardization and Quality Control Department; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
O V OmelyanskayaManaging Director of Units of Science Directorate; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.
Y A VasilevPhD, Chief Medical Officer; Scientific and Practical Center for Diagnostics and Telemedicine, Moscow City Healthcare Department, Bldg 1, 24 Petrovka St., Moscow, 127051, Russia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Materials and Methods: The vertebra was made using 3D printing by a digital model obtained from DICOM files of the abdominal CT examination. The phantom construction consists of three layers of different X-ray density. In the base made of photopolymer resin there is a cylindrical recess filled with a plastic mixture to imitate the normal state of the spongy substance (high density), osteopenia (moderate density decrease) and osteoporosis (significant decrease in density). Mineral density is regulated by changing β-tricalcium phosphate concentration. The cortical layer is modelled by applying metal foil on the base surface. Results: In X-ray tube voltage of 120 kV, the mean square deviations of the measured X-ray density values of the vertebral body, spongy substance and the cortical layer were 12.40, 3.96, and 57.23 HU, respectively. The mineral density assessment of the spongy substance for three X-ray tube voltages (100, 120, 140 kV) showed the mean absolute error to be 7.4 mg/ml, and the mean relative error - 7.3% (variation coefficient). The correction coefficient equal 7 mg/ml was used to correct the values, and after using the coefficient the mean absolute error decreased up to 0.4 mg/ml, and the mean relative error - up to 0.4% (variation coefficient). The relative measurement errors of the ventral, medial and dorsal vertebral body dimensions were 3.6, 2.7, and 2.9%, respectively. Conclusion: The methods used in developing a vertebral model can be applied in modeling the entire range of the mineral density of bone spongy substance: from osteoporosis to norm. The developed model demonstrates high stability of X-ray characteristics and anatomical accuracy; therefore, it can be used for equipment calibration, quality control of diagnostic systems, and in the training process to demonstrate the bone structure changes.

Indexed as

Bone DensityLumbar VertebraeModels, AnatomicPhantoms, ImagingAbsorptiometry, PhotonHumansdensitometryosteoporosisphantomvertebra

Identifiers

PMID41427069
PMCPMC12715482

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.