Evidence map›Paper›PMID 41426920›Full record

ArticleCureus2025

Assessment of Surface Roughness of Composite Resins Polished With Different Systems and Speeds: A Comparative In Vitro Study.

Anupma Solanki, Rishi Manan, Charu Dayal, Mahesh Mohan, Ankit Gupta, Nadeem Ashiq, Seema Gupta

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anupma SolankiDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Rishi MananDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Charu DayalDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Mahesh MohanDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Ankit GuptaDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Nadeem AshiqDepartment of Conservative Dentistry and Endodontics, Institute of Dental Studies and Technologies, Modinagar, IND.
Seema GuptaDepartment of Orthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe surface smoothness of resin composite restorations is critical for their esthetic appeal and clinical longevity because rough surfaces may promote bacterial adhesion and compromise durability. This study aimed to compare the surface roughness of nanofilled resin composite restorations polished with Enhance, Sof-Lex Diamond, and Shape Guard systems at high and low speeds using Mylar strip-finished samples as a control. The objectives were to evaluate intergroup differences in surface roughness via profilometry, assess the impact of polishing speed, and identify the most effective system for achieving minimal roughness to enhance clinical outcomes. MATERIALS AND

methodsSeventy cylindrical composite discs (8 mm diameter × 4 mm depth) were fabricated using a nanofilled resin composite, polymerized with a curing unit, and stored in distilled water at 37°C for 24 h. Ten samples cured against Mylar strips served as the control group (Group 4) without further polishing. The remaining 60 samples were roughened with 600-grit sandpaper and randomly assigned to three groups (20 samples each): Group 1 (Enhance), Group 2 (Sof-Lex Diamond), and Group 3 (Shape Guard). Each group was subdivided into high-speed (15,000 revolutions per minute (rpm)) and low-speed (5,000 rpm) subgroups (10 samples each). Polishing was performed for 20 s under dry conditions using a micromotor with a contra-angle hand piece. The surface roughness (Ra, µm) was measured using a calibrated stylus profilometer, using three readings per sample to calculate the mean values. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey's post hoc test (p < 0.05).

resultsThe Mylar control group exhibited the lowest mean surface roughness (0.21 ± 0.07 µm). Among polished groups, Sof-Lex at high speed produced the smoothest surface (0.23 ± 0.07 µm), followed by Shape Guard at high speed (0.27 ± 0.09 µm). The Enhance system at low speed yielded the highest surface roughness (0.42 ± 0.14 µm). ANOVA confirmed significant differences among the groups (p = 0.001), thus rejecting the null hypothesis. Sof-Lex and Shape Guard at high speed matched the smoothness of the control, whereas Enhance performed inferiorly.

conclusionThe Sof-Lex Diamond and Shape Guard systems, particularly when utilized at elevated velocities, achieved superior surface smoothness that closely competed with Mylar-finished controls. These systems are recommended for clinical use to optimize restoration esthetics and durability, although further in vivo studies are needed to confirm their long-term performance.

Indexed as

composite resinin-vitro studypolishingspeedsurface roughness

Identifiers

PMID41426920
PMCPMC12716964

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.