ArticlePatient safety in surgery2025
Retained fragmented Raytec gauze eluding an alleged correct postoperative count following cardiothoracic surgery: case report of a rare "never event".
Article in Patient safety in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The safety of radiofrequency surgical sponges in orthopedic surgery: a validation study in 2,251 arthroplasty procedures.Patient safety in surgery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionRetained surgical items are rare yet serious complications that may occur despite correct instrument and sponge counts. Surgical sponges remain the most frequently retained items, with gauze marker strand retention being an uncommon mechanism. CASE PRESENTATION: A 69-year-old male with severe mitral regurgitation and triple-vessel coronary artery disease underwent mitral valve replacement with coronary artery bypass grafting. All surgical counts were verified as correct at the conclusion of surgery. Postoperative chest radiography, however, revealed two linear radio-opaque foreign bodies near the left lower sternum. Mediastinal re-exploration identified two radio-opaque strands, measuring 3.0 cm and 2.0 cm, attached to the left lower chest wall near the internal mammary artery stump. These were confirmed to be detached marker strands from Raytec gauzes. The patient's recovery was uneventful and he was discharged well.
conclusionThis case illustrates that retained gauze fragments can occur despite correct counts due to fragmentation of radiopaque markers. Surgeons and operating room nurses should inspect gauzes for integrity, maintain vigilance when manipulating sponges in confined operative fields, and consider adjunct technologies such as radiofrequency or barcode tracking. In high-risk surgeries, postoperative imaging may be warranted even with accurate counts to ensure patient safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.