Evidence map›Paper›PMID 41420660›Full record

ArticleSurgical endoscopy2026

Surgical device malfunction in pediatric surgery: manufacturer and user facility device experience (MAUDE) database study.

Ayaka Tsutsumi, Richard S Herman, Shin Miyata

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ayaka TsutsumiDepartment of Pediatric Surgery, SSM Health Cardinal Glennon Children's Hospital, 1465 S Grand Blvd, St. Louis, MO, 63104, USA. ayaka.tsutsumi@health.slu.edu.ORCID 0009-0008-6511-9666
Richard S HermanDepartment of Pediatric Surgery, SSM Health Cardinal Glennon Children's Hospital, 1465 S Grand Blvd, St. Louis, MO, 63104, USA.
Shin MiyataDepartment of Pediatric Surgery, SSM Health Cardinal Glennon Children's Hospital, 1465 S Grand Blvd, St. Louis, MO, 63104, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe increasing prevalence of laparoscopic surgery in pediatric cases underscores the critical importance of surgical device safety. However, research specifically examining device malfunctions in pediatric procedures remains limited. This retrospective database study aims to characterize the types of surgical stapler and energy device malfunctions encountered within the pediatric population.

methodsThis study is a retrospective analysis of the Manufacturer and User Facility Device Experience (MAUDE) database to identify reported malfunctions of energy devices (Harmonic, Thunderbeat, LigaSure, and CoolSeal) and surgical staplers in pediatric patients. The review encompassed reports from 2017 to 2023, focusing exclusively on patients aged 18 and under. Duplicate entries were eliminated by comparing patient age, incident date, and incident descriptions. Reports involving animal studies, adult patients, or those lacking patient age information were excluded from the analysis.

resultsFrom a pool of 12,040 incident reports, 75 (0.61%) pertained to pediatric patients. After eliminating redundancies, 61 distinct cases were examined, encompassing malfunctions of surgical staplers (n = 31), Thunderbeat (n = 8), LigaSure (n = 20), and CoolSeal (n = 2). No deaths were recorded. A significant proportion (83.9%) of surgical stapler malfunctions involved the JustRight 5 mm Stapler, with the primary issue being failure to form a complete staple line. In LigaSure and CoolSeal, the predominant problem was sealing failure. Thunderbeat most frequently exhibited material fragmentation. Overall, 36.1% of the incidents resulted in patient injury, including bleeding (with one transfusion), bowel perforations, and bowel obstructions. Two cases required conversion to open surgery, and five necessitated additional surgical interventions. No root cause of malfunction was identified.

conclusionAlthough surgical devices undergo stringent safety protocols, malfunctions continue to be reported. The voluntary nature of the MAUDE database likely contributes to an underestimation of the true incidence of these events. Consequently, further research is warranted to comprehensively understand the nature and patient impact of device malfunctions.

Indexed as

Equipment FailureLaparoscopySurgical StaplersAdolescentChildChild, PreschoolDatabases, FactualFemaleHumansInfantMaleRetrospective StudiesEnergy devicesMAUDEPediatric surgerySurgical device malfunctionSurgical stapler

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.