Evidence map›Paper›PMID 41420264›Full record

ArticleMagnetic resonance in medicine2026

Time-Division Multiplexing for Parallel Transmission at Ultra-High Field With Limited RF Channels.

Felix Glang, Georgiy A Solomakha, Dario Bosch, Klaus Scheffler, Nikolai I Avdievich

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Felix GlangMagnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID https://orcid.org/0000-0003-3506-4947
Georgiy A SolomakhaMagnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID https://orcid.org/0000-0002-3024-0545
Dario BoschMagnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID https://orcid.org/0000-0002-6537-6370
Klaus SchefflerMagnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID https://orcid.org/0000-0001-6316-8773
Nikolai I AvdievichMagnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.ORCID https://orcid.org/0000-0001-7608-0869

Funding

Deutsche Forschungsgemeinschaft 530130666European Research Council 834940Max-Planck-Gesellschaft
6 · The paper itself

Abstract

purposeInvestigating time-division multiplexing for parallel transmission in ultra high-field imaging, striving for homogeneous whole brain excitation with a limited number of RF channels.

methodsA fast RF switch was built to alternately route 8 transmit channels to each row of a double-row 16-element transmit coil array at a 9.4 T human MRI system. Methods for SAR monitoring and pulse design for this temporal degree of freedom were developed and investigated in electromagnetic simulations and in vivo measurements, employing parallel transmission kT points pulses aiming for homogeneous whole-brain excitation. The achievable trade-off between local SAR and excitation homogeneity was compared for multiplexed and simultaneous transmission.

resultsUsing time-division multiplexing, similar excitation fidelity as with 16 transmit channels can be achieved with only 8 channels. For instance, multiplexing reduces the flip angle inhomogeneity by 2.22-fold compared to exciting only a single row of the array, and by 1.85-fold compared to statically splitting and routing 8 channels to 16 transmit coil elements. As a trade-off, compared to simultaneous excitation, multiplexing requires either increased pulse duration or amplitudes, the latter causing increased SAR. However, with appropriate SAR-aware pulse design, the multiplexing-induced local SAR increase can be controlled. This allows for viable pulse design solutions for the considered low-flip-angle imaging scenarios.

conclusionTime-division multiplexing allows driving a larger number of transmit elements with a smaller number of RF channels, resulting in improved parallel transmission performance. This opens up new possibilities for using advanced multi-row transmit coil arrays in sites with only 8 RF channels available.

Indexed as

BrainMagnetic Resonance ImagingAlgorithmsComputer SimulationEquipment DesignHumansImage Processing, Computer-AssistedPhantoms, ImagingRadio Wavesflip angle homogeneityhigh‐field MRImultiplexingRF switchSAR

Identifiers

PMID41420264
PMCPMC12962223

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.