Evidence map›Paper›PMID 41419844›Full record

ArticleBMC musculoskeletal disorders2025

Biomechanical comparison of double mini-locking plate versus lateral locking plate for Danis-Weber B distal fibula fractures.

Xiao Wang, Yongchang Chen, Li Dong, Gadisa Musa Wako, Yidong Xu, Fei Xiao, Haibo Xu

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiao Wang *Department of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China.
Yongchang Chen *Department of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China.
Li DongDepartment of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
Gadisa Musa WakoDepartment of General Surgery, Nanjing First Hospital, Nanjing Medical University, 919 Yingtian Street, Nanjing, 210019, China.
Yidong XuDepartment of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China.
Fei XiaoDepartment of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China. xiaofei_nanjing@163.com.
Haibo XuDepartment of Orthopaedics, Nanjing Qixia District Hospital, 28 Yaojia Road, Nanjing, 210046, China. 522673685@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLateral locking plate (LLP) is a successful standard treatment for Danis-Weber B distal fibula fractures. However, its uniplanar nature can be a limitation when insufficient bone is available at the distal fragment for secure screw fixation, particularly in low or osteoporotic fractures. This study evaluated the biomechanical performance of a novel biplanar double mini-locking plate (DMLP) system designed to address this challenge.

methodsTwenty left fibula Sawbones models were used to simulate Danis-Weber B fractures. The samples were divided into two groups, Group A (DMLP) and Group B (LLP), with 10 samples in each group. Biomechanical testing included quasistatic axial compression, torsional loading, and torsional failure tests to assess the stiffness, displacement, failure mode, and failure torque.

resultsBiomechanical testing revealed that Group A exhibited superior structural properties compared with Group B. In the axial compression test, the compression stiffness of Group A was 31% greater than that of Group B (402.8 ± 100.4 N/mm vs. 308.4 ± 60.51 N/mm, p = 0.0202). In the torsion tests, Group A demonstrated significantly greater torsional stiffness within the 0.25–0.5 N·m range (0.42 ± 0.05 N·m/° vs. 0.29 ± 0.17 N·m/°, p = 0.0172) and the 0.5–1.0 N·m range (0.39 ± 0.03 N·m/° vs. 0.27 ± 0.16 N·m/°, p = 0.0191). Additionally, the failure torque in Group A was approximately 26% greater (14.21 ± 2.01 N·m vs. 11.24 ± 1.47 N·m, p = 0.0036). Digital image correlation (DIC) analysis revealed that Group A had significantly reduced relative displacement at the fracture site under axial compression (-0.12 ± 0.06 mm vs. -0.32 ± 0.15 mm, p = 0.0011) and at 10° of torsion (0.68 ± 0.14 mm vs. 1.23 ± 0.21 mm, p < 0.0001). All fractures occurred at the proximal end, with no significant difference in failure location between the two groups (p = 1.000).

conclusionIn this in vitro biomechanical study using Sawbones models, the DMLP demonstrated superior performance compared to the LLP for the fixation of simulated Danis-Weber B distal fibula fractures. Under the quasistatic loading conditions tested, the DMLP construct exhibited significantly greater axial stiffness, torsional stability, and failure torque. These findings provide a strong biomechanical rationale, based on this standardized experimental model, warranting further investigation for its potential clinical application. CLINICAL TRIAL NUMBER: Not applicable.

Indexed as

Bone PlatesFibulaFibula FracturesFracture Fixation, InternalBiomechanical PhenomenaBone ScrewsHumansBiomechanicsDanis-Weber bDistal fibula fractureDouble mini-locking plateLateral locking plateSawbones

Identifiers

PMID41419844
PMCPMC12750925

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.