Evidence map›Paper›PMID 41417305›Full record

ArticleJornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia2025

Development and preliminary tests of a portable volumetric capnograph for outpatient use.

Francisco Ubaldo Vieira Junior, Denilson Antônio Marques, Natalie Camila Dos Reis Silva, Maria Ângela Gonçalves de Oliveira Ribeiro, Marcos Melo Moreira, Ilma Aparecida Paschoal, Isadora Minuzzi Vieira, Eduardo Tavares Costa

Abstract readValidation Study
In one paragraph

Article in Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Francisco Ubaldo Vieira Junior. Instituto Federal de Educação, Ciência e Tecnologia de São Paulo - IFSP - Campus Campinas, Campinas (SP) Brasil.ORCID http://orcid.org/0000-0003-0419-6971
Denilson Antônio Marques. Faculdade de Engenharia Elétrica e de Computação, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0009-0007-5830-8947
Natalie Camila Dos Reis Silva. Faculdade de Engenharia Elétrica e de Computação, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0009-0003-6607-3456
Maria Ângela Gonçalves de Oliveira Ribeiro. Faculdade de Ciências Médicas, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0000-0002-9418-1919
Marcos Melo Moreira. Faculdade de Ciências Médicas, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0000-0002-2148-5479
Ilma Aparecida Paschoal. Faculdade de Ciências Médicas, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0000-0002-0539-4243
Isadora Minuzzi Vieira. Faculdade de Engenharia Elétrica e de Computação, Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0009-0009-7212-6896
Eduardo Tavares Costa. Centro de Engenharia Biomédica - CEB - Universidade Estadual de Campinas - UNICAMP - Campinas (SP) Brasil.ORCID http://orcid.org/0000-0001-6787-5205

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo develop and validate a portable volumetric capnograph for collecting data on ventilatory mechanics during spontaneous breathing for outpatient use.

methodsThe device was developed by integrating the following commercially available sensors: a Hamilton® flow sensor (variable orifice; Hamilton Medical AG, Graubünden, Switzerland); an SDP810-125PA differential pressure sensor (Sensirion AG, Stäfa, Switzerland); and a Capnostat 5 CO2 sensor (Philips Respironics, Murrysville, PA, USA). An Arduino UNO-R3® microcontroller (Arduino, Monza, Italy) was used as an interface between the sensors and a laptop computer, and a Python application was used to acquire data at 10 ms intervals (100 Hz). Validation included static tests (flow: 0-45 L/min; partial pressure of CO2: 0-100 mmHg) and tests with five healthy volunteers (n = 115 respiratory cycles), in comparison with the reference equipment (a CO2SMO Plus® DX-8100 oxycapnograph; Philips Respironics).

resultsThe static tests showed excellent linear correlation for flow and CO2 concentration. For the tests conducted with the five volunteers, no significant differences were observed between the portable volumetric capnograph and the reference equipment for any of the variables analyzed. Intracycle variability was observed in the capnography curves, reflecting the physiological characteristics of spontaneous breathing.

conclusionsOur portable volumetric capnograph demonstrated the ability to collect accurate data on flow and partial pressure of CO2 during spontaneous breathing, with performance equivalent to that of the reference equipment. The variability in the capnography curves represents an intrinsic characteristic of spontaneous breathing that must be considered when developing algorithms for calculating physiological indicators.

Indexed as

CapnographyRespiratory MechanicsAdultCarbon DioxideEquipment DesignFemaleHumansMaleMiddle AgedOutpatientsReproducibility of ResultsYoung AdultCarbon Dioxide

Identifiers

PMID41417305
PMCPMC13143798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.