Evidence map›Paper›PMID 41417158›Full record

ArticleAnnals of biomedical engineering2026

Finite Element Investigation of Protective K-Wire Contribution to Hinge Fracture Prevention in Distal Femoral Osteotomy.

Sohrab Rezaei, Yamen Othmani, Massamaesso Bilasse, Samuel Berthe, João Luiz Machado Junior, Nadia Bahlouli, Matthieu Ehlinger

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sohrab RezaeiICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France. srezaeilafmejani@unistra.fr.ORCID http://orcid.org/0009-0003-7628-4169
Yamen OthmaniICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.
Massamaesso BilasseICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.
Samuel BertheICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.
João Luiz Machado JuniorICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.
Nadia BahlouliICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.
Matthieu EhlingerICube-Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie, UMR 7357, Université de Strasbourg, 4 Rue Blaise Pascal, 67000, Strasbourg, France.

Funding

ITI HealthTech, University of Strasbourg ITI 2021-2028
6 · The paper itself

Abstract

purposeDistal femoral osteotomy (DFO) is an effective surgical procedure to correct valgus knee deformities. However, in lateral opening-wedge DFO (LOW-DFO), medial hinge fracture is a common complication that can lead to instability, correction loss, and delayed healing. This study aims to develop and validate a finite element (FE) model to investigate the mechanical effect of a protective Kirschner wire (K-wire) inserted in the medial hinge on the risk of hinge fracture.

methodsA 3D finite element model of the opening stage in LOW-DFO was developed based on a prior experimental study on 3D-printed femurs. Crack initiation and propagation leading to fracture were simulated using the extended finite element method (XFEM). Two scenarios were compared: one with a protective K-wire and one without. Characterization tests were performed to obtain the necessary mechanical properties.

resultsThe model was validated against data from previous mechanical experiments. The results showed that, while the protective K-wire had minimal effect on the location or onset of crack initiation, it increased the hinge stiffness and stabilized crack propagation. Compared to the configuration without the wire, the K-wire reduced the severity of unstable crack growth, thereby limiting abrupt failure.

conclusionsThe use of a protective K-wire improves the mechanical stability of the medial hinge by moderating crack propagation without affecting the initiation threshold. This study highlights the importance of modeling crack propagation and not only initiation when evaluating fracture risk in DFO. The findings support the potential clinical benefit of K-wire insertion for preventing hinge-related complications.

Indexed as

Bone WiresFemoral FracturesFemurFinite Element AnalysisModels, BiologicalOsteotomyHumansCrack modelingDistal femoral osteotomyHinge fractureKirschner wireXFEM

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked