Evidence map›Paper›PMID 41416735›Full record

ArticleInvestigative radiology2025

Ready for Routine: Homogeneous, High-Resolution, and Multicontrast Whole-Brain MRI at 7 Tesla in Short Scan Time With "plug-and-Play" pTx Sequences.

Jennifer Faber, Daniel Paech, Eberhard Pracht, Rüdiger Stirnberg, Philipp Ehses, Yannik Völzke, Daniel Löwen, Mónica Ferreira, Sascha Brunheim, Nicolas Boulant and 14 more

Abstract read
In one paragraph

Article in Investigative radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Magnetic resonance imaging.Science advances · 2026
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

24 authors.

Daniel Paech
Eberhard Pracht
Rüdiger Stirnberg
Philipp Ehses
Yannik Völzke
Daniel Löwen
Mónica Ferreira
Sascha Brunheim
Nicolas Boulant
Vincent Gras
Franck Mauconduit
Aurélien Massire
Pål Erik Goa
Laurent Lamalle
Theodor Rüber
Tobias Bauer
Gabor C Petzold
Julia Nordsiek
Matthias Schneider
Christina Schaub
Thomas Klockgether
Alexander Radbruch
Tony Stöcker

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background7T MRI received FDA/CE clearance almost 7 years ago. However, until today, it has not yet been widely adopted in clinical routine. This is mainly due to field inhomogeneities that impede whole-brain coverage. Moreover, the long scan times often associated with high-resolution imaging are an additional limiting factor. PURPOSE: To combine calibration-free parallel transmit technology (pTx) using universal pulses (UP) with advanced imaging acceleration strategies to achieve homogenous multicontrast 7T MRI with whole-brain coverage and high spatial resolution in short scan time. MATERIALS AND

methodsTen healthy volunteers were scanned both with conventional vendor-provided sequences and with custom sequences for anatomical whole-brain imaging [-weighted, -weighted, FLAIR, and susceptibility-weighted]. The scan times for the 2 anatomical protocols were matched (25 minutes). In addition, a quantitative MRI protocol [multi-parametric mapping (MPM) and chemical exchange saturation transfer (CEST)] was scanned twice using custom sequences with conventional (circular polarized) and UPs, respectively, in a scan time of 2×25 minutes. Moreover, 4 patients with different neurological diseases were scanned, namely temporal lobe epilepsy, spinocerebellar ataxia, cerebral amyloid angiopathy, and glioblastoma. For the patients, only optimized custom sequences with UPs were acquired.

resultsCompared with conventional implementations, the custom sequences provide strongly improved image homogeneity and quality with significantly higher SNR and CNR across the whole brain, including cerebellum and brain stem. Moreover, UPs improve the repeatability of derived quantitative parameters. The suggested protocol has additionally been successfully demonstrated in 4 patients with different neurological pathologies.

conclusionsHomogeneous whole-brain 7T MRI with high spatial resolution and high image quality is possible in clinically feasible scan times. The developed protocol can be applied without any expert knowledge and is ready for clinical use. The approach could largely extend applicability of UHF MRI in neuroradiology paving the way for increased routine use of 7T MRI.

Indexed as

7T7 TeslaCESTinfratentorial structuresMPMMPRAGEneuroradiologypTxultra-high field

Identifiers

PMID41416735
PMCPMC13117539

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.