Evidence map›Paper›PMID 41414766›Full record

ArticleJournal of applied clinical medical physics2026

Patient-specific quality assurance for extremely small field sizes using 3D in vivo dosimetry in fractionated stereotactic radiosurgery for brain metastases.

Kenichi Jumonji, Jun Takatsu, Naoya Hara, Ruiheng Fan, Risa Shimomura, Tatsuya Inoue, Kotaro Iijima, Noriyuki Okonogi, Naoya Murakami, Naoto Shikama

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kenichi JumonjiDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.
Jun TakatsuDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.ORCID https://orcid.org/0000-0001-9848-9251
Naoya HaraDepartment of Radiology, Juntendo University Hospital, Bunkyo-ku, Tokyo, Japan.
Ruiheng FanDepartment of Radiology, Juntendo University Hospital, Bunkyo-ku, Tokyo, Japan.
Risa ShimomuraDepartment of Radiology, Juntendo University Hospital, Bunkyo-ku, Tokyo, Japan.
Tatsuya InoueDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.ORCID https://orcid.org/0000-0003-0001-7921
Kotaro IijimaDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.
Noriyuki OkonogiDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.
Naoya MurakamiDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.
Naoto ShikamaDepartment of Radiation Oncology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFractionated stereotactic radiosurgery (fSRS) using LINAC-based volumetric-modulated arc therapy (VMAT) has become widely adopted and achieved favorable outcomes. However, this technique involves extremely small field sizes, making pre-treatment quality assurance (QA) with high-resolution detectors essential. PURPOSE: This study aimed to evaluate the error detection sensitivity and utility of EPID using 3D in vivo dosimetry based on dose-volume histogram (DVH) analysis for brain fSRS pre-treatment QA.

methodsVMAT plans were generated for spherical planning target volumes (PTVs) with diameters of 1-3 cm centered in SRS MapCHECK. A monitor unit (MU) output error was introduced in increments, and the leaf gap width was systematically opened and closed. Finally, multi-leaf collimator (MLC) shift errors were applied. The error detection sensitivity was evaluated with these intentional errors. We compared this with the SRS MapCHECK 2D gamma analysis conventionally used in pre-treatment QA. For in vivo dosimetry, 3D dose calculations were performed with PerFRACTION using cine-mode electronic portal imaging device images and log files. DVH parameters such as D98%, D95%, D2%, and average doses of the PTV were compared between the base plan and the error plans. The 2D gamma analysis was performed using global gamma of 3%/2 mm, 3%/1 mm, 2%/2 mm, 2%/1 mm, and 1%/1 mm.

resultsThe 2D gamma analysis revealed no MU output errors for the 1 cm target across all criteria. The 2%/1 mm criterion effectively detected errors in leaf gap width and MLC shifts in some cases. Conversely, all error types were detected by 3D in vivo dosimetry using D95% of the target.

conclusionIn pre-treatment QA for brain fSRS, 3D in vivo dosimetry based on DVH analysis demonstrated superior error detection sensitivity compared to conventional 2D gamma analysis. Our results suggest that 3D in vivo dosimetry is a useful tool for pre-treatment QA in brain fSRS.

Indexed as

Brain NeoplasmsImaging, Three-DimensionalIn Vivo DosimetryQuality Assurance, Health CareRadiosurgeryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansOrgans at RiskParticle AcceleratorsPhantoms, ImagingRadiometryRadiotherapy Dosage3D in‐vivo dosimetryerror detection sensitivitypatient‐specific QAPerFRACTIONsmall field

Identifiers

PMID41414766
PMCPMC12715341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.