Evidence map›Paper›PMID 41413423›Full record

ArticleScientific reports2025

Experimental evaluation of silicon carbide P-N detectors under thermal and fast neutron irradiation at the RA-6 nuclear research reactor.

Martín Pérez, Juan Jerónimo Blostein, Felipe Zamorano, Celeste Fleta, Julio Marín, Giulio Pellegrini, Consuelo Guardiola

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Martín PérezInstitute of Microelectronics of Barcelona (IMB-CNM-CSIC), Cerdanyola del Vallès (Bellaterra), 08193, Spain. martin.perez@ib.edu.ar.
Juan Jerónimo BlosteinComisión Nacional de Energía Atómica (CNEA), Av. Bustillo 9500, San Carlos de Bariloche, Río Negro, Argentina.
Felipe ZamoranoInstitute of Microelectronics of Barcelona (IMB-CNM-CSIC), Cerdanyola del Vallès (Bellaterra), 08193, Spain.
Celeste FletaInstitute of Microelectronics of Barcelona (IMB-CNM-CSIC), Cerdanyola del Vallès (Bellaterra), 08193, Spain.
Julio MarínComisión Nacional de Energía Atómica (CNEA), Av. Bustillo 9500, San Carlos de Bariloche, Río Negro, Argentina.
Giulio PellegriniInstitute of Microelectronics of Barcelona (IMB-CNM-CSIC), Cerdanyola del Vallès (Bellaterra), 08193, Spain.
Consuelo GuardiolaInstitute of Microelectronics of Barcelona (IMB-CNM-CSIC), Cerdanyola del Vallès (Bellaterra), 08193, Spain. consuelo.guardiola@imb-cnm.csic.es.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Silicon carbide (SiC) detectors present key advantages for neutron detection in harsh radiation environments, including high radiation hardness, low leakage current, and excellent thermal stability. In this work, we report on the characterization of SiC P–N diodes manufactured at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC) for both thermal and fast neutron detection. For thermal neutron measurements, 50 µm and 100 µm SiC diodes coupled to a 6LiF conversion layer were tested at the RA-6 Nuclear Research Reactor, San Carlos de Bariloche, Argentina. The detectors exhibited a linear response with reactor power up to 500 kW, with no evidence of saturation or dead-time effects, and an intrinsic detection efficiency of (4.39±0.22)%. The detection efficiency was characterized as a function of the neutron incidence angle, showing a monotonic increase. For fast neutrons, 100 µm diodes coupled to polypropylene layers of varying thicknesses were characterized using an AmBe source. The results showed that the intrinsic detection efficiency increased with converter thickness, reaching a maximum value of (0.57±0.04)% for an 800 µm layer. PHITS Monte Carlo simulations reproduced the experimental data, validating the interpretation of the measured spectra. These results confirm the potential of SiC-based detectors for reliable monitoring of thermal and fast neutrons in environments with high gamma background, including radiotherapy, nuclear reactors, and others.

Indexed as

Fast neutron detectionRadiation hard detectorsSilicon carbideThermal neutron detection

Identifiers

PMID41413423
PMCPMC12815908

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.