Evidence map›Paper›PMID 41413050›Full record

ArticleNature communications2025

High temperature evaporative cooler utilizing boiling suppression at water's boiling point.

Ranran Fang, Zeyu Sun, Quan Chen, Jiangen Zheng, Zhonghua Yan, Nana Pan, Yi Li, Yongyi Deng, Yongbin Wei, Zhu Liang and 1 more

Abstract read
In one paragraph

Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ranran FangSchool of Integrated Circuits, Chongqing University of Posts and Telecommunications, Chongqing, China. fangrr@cqupt.edu.cn.ORCID http://orcid.org/0000-0003-1932-6652
Zeyu SunSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Quan ChenSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Jiangen ZhengSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China. zhengjg@cqupt.edu.cn.
Zhonghua YanSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China. yanzh@cqupt.edu.cn.ORCID http://orcid.org/0000-0002-0076-9691
Nana PanSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Yi LiSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Yongyi DengSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Yongbin WeiSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Zhu LiangSchool of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Anatoliy Y VorobyevSchool of Integrated Circuits, Chongqing University of Posts and Telecommunications, Chongqing, China. ayv@cqupt.edu.cn.ORCID http://orcid.org/0000-0002-0573-8624

Funding

National Natural Science Foundation of China (National Science Foundation of China) 12204082National Natural Science Foundation of China (National Science Foundation of China) 12402295National Natural Science Foundation of China (National Science Foundation of China) 62375033National Natural Science Foundation of China (National Science Foundation of China) W2531043
6 · The paper itself

Abstract

We experimentally demonstrate boiling suppression in a water film confined within superhydrophilic hierarchical nano/microstructured surfaces, enabling intense interfacial steam generation without bubble formation at the boiling point. Leveraging this phenomenon, we develop a high-temperature dew point evaporative cooler capable of reducing hot airflow from 437 °C to below ambient temperature. The cooler also performs effectively below the boiling point, lowering inlet air from 43 °C to 16.7 °C. These findings open pathways for potential practical applications of dew point evaporative cooling in power generation, internal combustion engines, and generative AI systems.

Identifiers

PMID41413050
PMCPMC12848043

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.