Evidence map›Paper›PMID 41410711›Full record

ArticleNeurosurgical review2025

Curved trajectories in stereotactic neurosurgery: is it feasible?

Dörthe Keiner, Julian Mühlenhoff, Mohamed Henia, Fabian Rabel, Wolfgang Reith, Matthias K Hoffmann, Kathrin Flaßkamp, Karl Worthmann, Thomas Sattel, Joachim Oertel

Abstract read
In one paragraph

Article in Neurosurgical review, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Dörthe KeinerKlinik für Neurochirurgie, Universitätsklinikum des Saarlandes und Medizinische Fakultät, Universität des Saarlandes, Homburg/Saar, 66421, Germany.
Julian MühlenhoffMechatronics Group, Technische Universität Ilmenau, Ilmenau, Germany.
Mohamed HeniaKlinik für Neurochirurgie, Universitätsklinikum des Saarlandes und Medizinische Fakultät, Universität des Saarlandes, Homburg/Saar, 66421, Germany.
Fabian RabelMechatronics Group, Technische Universität Ilmenau, Ilmenau, Germany.
Wolfgang ReithKlinik für diagnostische und interventionelle Neuroradiologe, Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes, Homburg, Germany.
Matthias K HoffmannSystems Modeling and Simulation, Saarland University, Saarbrücken, Germany.
Kathrin FlaßkampSystems Modeling and Simulation, Saarland University, Saarbrücken, Germany.
Karl WorthmannMechatronics Group, Technische Universität Ilmenau, Ilmenau, Germany.
Thomas SattelMechatronics Group, Technische Universität Ilmenau, Ilmenau, Germany.
Joachim OertelKlinik für Neurochirurgie, Universitätsklinikum des Saarlandes und Medizinische Fakultät, Universität des Saarlandes, Homburg/Saar, 66421, Germany. oertelj@freenet.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveStereotactic procedures are planned and performed with straight trajectories. However, brain sulci with vessels and ventricles have to be avoided for bleeding and deviation risks. In distinct pathologies such as insular or pineal lesions, or in patients with brain atrophy, curved trajectories theoratically could provide superior results. So far, research on curved trajectories for stereotactic neurosurgery focusses on aspects like path planning, robot design and control. In a collaborative project of engineers, mathematicians, and neurosurgeons a prototype system for curved cannulas was developed using a concentric tube continuum robot (CTCR) platform.

methodsTarget precision and follow-the-leader-deviations by movements of the cannulas were assessed. For a set of automatically planned configurations by numerical optimization, the real robot behavior was compared to state-of-the-art models of elastostatic behavior. Target accuracy was tested with CT-imaging of a head model and a deep-seated target, calculation and transformation of stereotactic coordinates to the actuation system, and application of the curved cannulas to the target.

resultsDetermination of the model's target point via CT-scan and transformation of the stereotactic coordinates in the path planning software for curved trajectories were possible. The technical operation of the prototype was improved for mounting at the stereotactic system. The target could be calculated with optimal accuracy in the panned configuration by numerical optimization and the test procedure could be performed successfully. However, accuracy with curved cannulas in this prototype system had a target point deviation of 2 mm and more.

conclusionsTo the authors' knowledge, this is the first application of curved cannulas for stereotactic neurosurgery in a comparable way to clinical practice. Further research will have to address incorporating iterative learning control of the robot's tip position to reach target point deviations below 1 mm.

Indexed as

Neurosurgical ProceduresStereotaxic TechniquesBrainHumansRoboticsRobotic Surgical ProceduresTomography, X-Ray ComputedActuation systemConcentric tube continuum robotCurved trajectoryIntracranial stereotactic localizationStereotactic neurosurgery

Identifiers

PMID41410711
PMCPMC12715043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked