Evidence map›Paper›PMID 41409846›Full record

ArticleSurgical neurology international2025

Factors affecting targeting accuracy in minimally invasive twist drill deep brain stimulation.

Abteen Mostofi, Teresa R Scott, Bryony Kiyoka Ishihara, Fotios Bourlogiannis, Michael G Hart, Erlick A Pereira

Abstract read
In one paragraph

Article in Surgical neurology international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Abteen MostofiDepartment of Psychology and Neuroscience, City St George's, University of London, London, United Kingdom.
Teresa R ScottDepartment of Psychology and Neuroscience, City St George's, University of London, London, United Kingdom.
Bryony Kiyoka IshiharaDepartment of Psychology and Neuroscience, City St George's, University of London, London, United Kingdom.
Fotios BourlogiannisDepartment of Neurosurgery, Atkinson Morley Regional Neurosciences Centre, London, United Kingdom.
Michael G HartDepartment of Psychology and Neuroscience, City St George's, University of London, London, United Kingdom.
Erlick A PereiraDepartment of Psychology and Neuroscience, City St George's, University of London, London, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The efficacy of deep brain stimulation (DBS) relies on accurate stereotactic electrode placement. Post-implantation imaging enables assessment of electrode positioning and quantification of targeting accuracy. While DBS is typically performed through burr hole, this study examines targeting accuracy factors using a minimally invasive twist drill technique. Methods: We retrospectively analyzed 86 patients (171 electrodes) who underwent DBS at our institution. Different measures of targeting error were defined and compared. Analysis focused on trajectory error (TE), the closest perpendicular distance between the electrode's center and target locus. Seventeen demographic, clinical, and procedural variables were assessed for potential impact on accuracy. Multivariate mixed effects models were applied to identify significant associations. Results: Mean (±standard deviation) TE was 1.4 (0.7) mm. Electrodes tended to lie medial (0.3 ± 0.1 mm; mean ± 95% confidence interval), posterior (0.6 ± 0.1 mm), and superior (0.5 ± 0.1 mm) to targets. Three variables were independently and significantly associated with greater TE: use of one of two stereotactic frames (effect size 0.4 ± 0.2 mm), second-side implantation in bilateral surgery (0.3 ± 0.2 mm), and decreasing coronal approach angle (0.04 ± 0.03 mm/°). All three factors were associated with significantly more posterior implantation, while second-side and decreasing coronal angle also yielded a more superiorly located point of closest approach of the electrode. Conclusion: We present a thorough multivariate analysis of targeting accuracy in DBS, identifying significant factors associated with accuracy within our workflow. We suggest that such targeting error analysis should be performed routinely by neurosurgeons undertaking DBS to audit targeting accuracy and identify error sources within their workflows.

Indexed as

AccuracyDeep brain stimulationElectrodeStereotactic surgeryTargeting error

Identifiers

PMID41409846
PMCPMC12707720

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.