Evidence map›Paper›PMID 41409124›Full record

ArticleBiomaterial investigations in dentistry2025

Radio frequency sputtering of self-sanitizing material on NiTi archwires.

Mahmood Naser, Emad Al-Hassani, Fatima Al-Hassani

Abstract read
In one paragraph

Article in Biomaterial investigations in dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mahmood NaserDepartment of Materials Engineering, Faculty of Engineering, University of Kufa, Iraq.
Emad Al-HassaniCollege of Materials Engineering, University of Technology, Iraq.
Fatima Al-HassaniCollege of Materials Engineering, University of Technology, Iraq.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The objective of this study was to coat orthodontic nickel titanium (NiTi) archwires with nano-particles (NP) of silver (Ag) combined with nano polytetrafluoroethylene (PTFE) to produce a smooth antimicrobial nanocomposite layer by using a radio frequency (RF) sputtering process and to evaluate the coated surfaces in terms of morphology, nano-roughness, adhesion strength, hardness, and antimicrobial activity. Materials and methods: Super-elastic NiTi archwires (diameter = 0.4 mm, length = 160 mm) were surface cleaned and sterilized prior to the RF sputtering, using a mixture of nano Ag powder (20 nm; purity > 99.95%) and PTFE powder (25 nm; purity > 99.95%). X-ray diffraction apparatus (XRD), flex atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM) were used to characterize the morphology and nano roughness of the coated archwires. Results: A uniform and homogeneous nanocomposite coating was obtained without agglomeration. Surface roughness values decreased with increasing sputtering time, while the coated samples exhibited excellent antibacterial activity against both bacterial strains. AFM analysis demonstrated that sputtering time strongly influenced adhesion resistance, hardness, and coating stability, and the antibacterial activity was highly effective against both Conclusion: The sputtering time of 30 min gave a smooth coating layer on the surface of NiTi archwire with strong antimicrobial resistance that offers significant potential for dental applications.

Indexed as

Archwirecoatingnanoparticlesradio frequencyroughness

Identifiers

PMID41409124
PMCPMC12706999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.