Evidence map›Paper›PMID 41405751›Full record

ArticleIntensive care medicine experimental2025

Prediction and prevention of ventilation impairments during bronchoscopy.

Ben Fabry, Navid Bonakdar, Christian Kuster, Johannes Bartl, Frederick Krischke, Roland Francis

Abstract read
In one paragraph

Article in Intensive care medicine experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ben FabryDepartment of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Henkestr. 91, 91052, Erlangen, Germany. ben.fabry@fau.de.ORCID http://orcid.org/0000-0003-1737-0465
Navid BonakdarDepartment of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Henkestr. 91, 91052, Erlangen, Germany.
Christian KusterDepartment of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Henkestr. 91, 91052, Erlangen, Germany.
Johannes BartlDepartment of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Henkestr. 91, 91052, Erlangen, Germany.
Frederick KrischkeDepartment of Anesthesiology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany.
Roland FrancisDepartment of Anesthesiology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBronchoscopy in ventilated patients narrows the endotracheal tube lumen and increases resistance, which can lead to hypoventilation and intrinsic PEEP build-up. These ventilation impairments depend on the geometry of the tube-bronchoscope combination, ventilator settings, and patient mechanics. Currently, no predictive method exists to quantify these impairments or guide compensatory strategies.

methodsWe measured pressure-flow relationships across multiple tube-bronchoscope configurations in a bench setup and derived a scaling law describing the nonlinear, flow-dependent resistance as a function of the effective tube diameter, defined as the diameter of a circular tube with the same open cross-sectional area as the remaining lumen. We then assessed the ventilatory consequences of bronchoscopy using an intensive care ventilator connected to an active lung simulator under both volume- and pressure-controlled modes.

resultsBronchoscope insertion sharply increases resistance, which scales with the inverse fifth power of the effective diameter. A simulation tool based on this scaling law accurately predicts the experimentally observed dynamic hyperinflation and intrinsic PEEP build-up in volume-controlled modes, as well as the reduced tidal volumes in pressure-controlled modes. Ventilation with automatic tube compensation during pressure control fully prevents both impairments.

conclusionsThe commonly cited recommendation of a ≥ 2 mm difference between endotracheal tube and bronchoscope diameters does not reliably prevent ventilation impairments during bronchoscopy. Our findings suggest that a quantitative framework, which accounts for ventilator settings, patient mechanics, and the effective tube diameter, can provide additional guidance for tube selection and help anticipate impairments. We demonstrate proof of principle that pressure-controlled ventilation with automatic tube compensation is a feasible strategy to mitigate bronchoscopy-induced ventilation impairments.

Indexed as

BronchoscopyEndotracheal tube resistanceHypoventilationIntrinsic PEEPMechanical ventilation

Identifiers

PMID41405751
PMCPMC12712257

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.