ArticleThe journal of extra-corporeal technology2025
Delta-P as an early indicator of oxygenator failure: the case for standardized manufacturer reference values.
Article in The journal of extra-corporeal technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparative Analysis of Pressure Drop (Δp): Hemodynamic Performance of Three Commercial Oxygenators During Cardiopulmonary Bypass.Artificial organs · 2026Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The evolution of extracorporeal membrane oxygenation (ECMO) has led to an increasing reliance on objective parameters to detect complications early and enhance patient safety. One such parameter is the transmembrane pressure gradient, more commonly referred to as delta P (ΔP), the difference between the inlet and outlet pressures of the oxygenator. This measure has increasingly been recognized as a critical early indicator of thrombus formation within the oxygenator during ECMO support. However, its interpretation remains complex and context-dependent, particularly because delta P values are significantly influenced by the design features of different ECMO circuits, including pump head geometry and oxygenator configuration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials