Evidence map›Paper›PMID 41404751›Full record

ArticleJournal of the American Heart Association2026

ECG-Capable Smartwatches Can Induce Magnet Mode in Cardiac Implantable Electronic Devices.

Felix K Wegner, Till Geisendörfer, Julian Wolfes, Benjamin Rath, Julia Köbe, Christian Ellermann, Moritz Martinovic, Christoph Kittl, Gerrit Frommeyer, Lars Eckardt

Abstract read
In one paragraph

Article in Journal of the American Heart Association, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Felix K WegnerDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.ORCID 0000-0001-9087-645X
Till GeisendörferDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.
Julian WolfesDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.
Benjamin RathDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.
Julia KöbeDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.
Christian EllermannDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.
Moritz MartinovicDepartment of Trauma, Hand and Reconstructive Surgery University Hospital Muenster Muenster Germany.
Christoph KittlDepartment of Trauma, Hand and Reconstructive Surgery University Hospital Muenster Muenster Germany.ORCID 0000-0002-8507-5735
Gerrit FrommeyerDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.ORCID 0000-0002-1431-9886
Lars EckardtDepartment of Cardiology II - Electrophysiology University Hospital Muenster Muenster Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSmartwatches are increasingly used for screening of tachyarrhythmias and for ECG recording. We therefore investigated possible mechanisms of magnet-mode induction of smartwatches in cardiac implantable electronic devices (CIED).

methodsFifteen CIED (5 pacemakers, 10 implantable cardioverter-defibrillators) from all manufacturers were implanted in a subcutaneous and submuscular location in an isolated porcine thorax and connected to an interactive heart simulator. Eight different smartwatches (3 Apple, 3 Samsung, 1 Huawei, 1 Withings) were placed on top of the implantation site in 3 different configurations, and signs of magnet mode induction were recorded.

resultsWhen the faces of smartwatches were placed on top of subcutaneously implanted CIED, only 1 instance of magnet mode induction was recorded in 120 measurements (<1%). When turning around the smartwatches and placing the backs on the implantation site, signs of magnet mode were recorded in 36 of 120 measured instances (30%). Smartwatches connected to respective chargers induced magnet mode in 28 of 120 measurements (23%). Magnet mode induction in submuscularly implanted CIED was seen in 5 of 360 measurements (1%). The smartwatch with physical charging connectors was the only one not to induce magnet mode in any CIED, resulting from a lower-than-average magnetic field strength likely due to its different charging mechanism.

conclusionsECG-capable smartwatches can induce magnet mode in CIED. Although the risk for patients wearing smartwatches on their wrist is low, patients should be discouraged from placing their watch close to their CIED. Smartwatch charging mechanism and CIED implantation depth influence the risk of magnet mode induction.

Indexed as

Defibrillators, ImplantableElectrocardiographyMagnetsPacemaker, ArtificialAnimalsEquipment DesignSwineApple Watchdefibrillatormagnetpacemakersmartwatch

Identifiers

PMID41404751
PMCPMC12909046

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.