Evidence map›Paper›PMID 41404528›Full record

ArticleComputer methods in applied mechanics and engineering2026

ValveFit: An analysis-suitable B-spline-based surface fitting framework for patient-specific modeling of tricuspid valves.

Ajith Moola, Ashton M Corpuz, Michael J Burkhart, Colton J Ross, Arshid Mir, Harold M Burkhart, Chung-Hao Lee, Ming-Chen Hsu, Aishwarya Pawar

Abstract read
In one paragraph

Article in Computer methods in applied mechanics and engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. A modelling study of right ventricular growth with valvular regurgitation.Biomechanics and modeling in mechanobiology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ajith MoolaDepartment of Mechanical Engineering, Iowa State University, Black Engineering Building, 2529 Union Drive, Ames, Iowa 50011, USA.
Ashton M CorpuzDepartment of Mechanical Engineering, Iowa State University, Black Engineering Building, 2529 Union Drive, Ames, Iowa 50011, USA.
Michael J BurkhartSchool of Aerospace and Mechanical Engineering, The University of Oklahoma, Felgar Hall, 865 Asp Avenue, Norman, Oklahoma 73019, USA.
Colton J RossSchool of Aerospace and Mechanical Engineering, The University of Oklahoma, Felgar Hall, 865 Asp Avenue, Norman, Oklahoma 73019, USA.
Arshid MirDepartment of Pediatrics, The University of Oklahoma Health Sciences Center, 1200 N. Children's Ave., Suite 2F, Oklahoma City, Oklahoma 73104, USA.
Harold M BurkhartDepartment of Surgery, The University of Oklahoma Health Sciences Center, 800 Stanton L. Young Blvd., Oklahoma City, Oklahoma 73104, USA.
Chung-Hao LeeDepartment of Bioengineering, University of California, Riverside, 900 University Ave., Riverside, California 92507, USA.
Ming-Chen HsuDepartment of Mechanical Engineering, Iowa State University, Black Engineering Building, 2529 Union Drive, Ames, Iowa 50011, USA.
Aishwarya PawarDepartment of Mechanical Engineering, Iowa State University, Black Engineering Building, 2529 Union Drive, Ames, Iowa 50011, USA.

Funding

Improving outcomes in endovascular treatment of intracranial aneurysms: Combining additive manufacturing, in-silico modeling, and shape memory polymersR01HL159475 · NHLBI · UNIVERSITY OF OKLAHOMA · PI Chung-Hao Lee · 2022 to 2026
$3.3M
Integrate Data-Driven Modeling and Multi-scale Measures Towards Tissue FunctionR01GM157589 · NIGMS · LEHIGH UNIVERSITY · PI YUE YU · 2024 to 2026
$890k
American Heart Association-American Stroke Association 16SDG27760143American Heart Association-American Stroke Association 24IVPHA1283213 - CHUNG-HAO LEENHLBI NIH HHS R01 HL159475NIGMS NIH HHS R01 GM157589
6 · The paper itself

Abstract

Patient-specific computational modeling of the tricuspid valve (TV) is vital for the clinical assessment of heart valve diseases. However, this process is hindered by limitations inherent in the medical image data, such as noise and sparsity, as well as by complex valve dynamics. We present ValveFit, a novel differentiable B-spline surface fitting framework that enables rapid reconstruction of smooth, analysis-suitable geometry from point clouds obtained via medical image segmentation. We start with an idealized TV B-spline template surface and optimize its control point positions to fit segmented point clouds via an innovative loss function, balancing shape fidelity and mesh regularization. Novel regularization terms are introduced to ensure that the surface remains smooth, regular, and intersection-free during large deformations. We demonstrate the robustness and validate the accuracy of the framework by first applying it to simulation-derived point clouds that serve as the ground truth. We further show its robustness across different point cloud densities and noise levels. Finally, we demonstrate the performance of the framework toward fitting point clouds obtained from real patients at different stages of valve motion. An isogeometric biomechanical valve simulation is then performed on the fitted surfaces to show their direct applicability toward analysis. ValveFit enables automated patient-specific modeling with minimal manual intervention, paving the way for the future development of direct image-to-analysis platforms for clinical applications.

Indexed as

Heart valvesIsogeometric analysisMedical imagingPatient-specific modelingPeriodic B-splinesSurface fitting

Identifiers

PMID41404528
PMCPMC12705065

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.