An Insight Into the Aerosolization Pattern of Formoterol Fumarate Dry Powder Inhalation Formulation Actuated Via Two Different Inhaler Devices.

Leila Asadollahi, Reza Ghanbari, Soheil Abbaspour-Ravasjani, Hamed Hamishehkar, Ali Nokhodchi

Abstract read
In one paragraph

Article in Advanced pharmaceutical bulletin, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Leila AsadollahiStudent Research Committee and Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.ORCID https://orcid.org/0000-0002-5919-2460
Reza GhanbariDepartment of Materials Science and Engineering, North Carolina State University, Raleigh, USA.
Soheil Abbaspour-RavasjaniDrug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Hamed HamishehkarDrug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.ORCID https://orcid.org/0000-0001-9905-0662
Ali NokhodchiSchool of Life Sciences, University of Sussex, Brighton, UK.ORCID https://orcid.org/0000-0002-3244-2482

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Effective inhaled drug delivery is essential for managing bronchial asthma and chronic obstructive pulmonary disease (COPD). This study compared the aerosolization efficiency of two different dry powder inhalers (DPIs), the Aerolizer and Revolizer, using a fixed formulation of formoterol fumarate. Methods: Aerodynamic particle size distribution was measured using a next-generation impactor (NGI), and delivered dose uniformity was assessed with a dosage unit sampling apparatus (DUSA), both at a fixed flow rate of 60 L/min. Drug content was quantified using a validated high-performance liquid chromatography (HPLC) method, and performance metrics were analyzed using CITDAS software. Data were averaged (mean±SD) and compared by statistical tests (e.g., ANOVA or t-tests), with Results: The Aerolizer achieved a fine particle dose (FPD) of 4.71 µg, which was 2.39 times higher than that of the Revolizer (1.97 µg). It also delivered approximately 20% greater overall dose and showed more consistent deposition in the NGI stages. While both devices demonstrated similar fine particle fractions (FPFS), the difference in FPD was primarily due to the higher emitted dose from the Aerolizer. The use of a fixed flow rate allowed direct comparison of device performance. Conclusion: These findings highlight the significant influence of device design on DPI performance, even when the formulation remains constant. The Aerolizer, a low-resistance inhaler, showed superior delivery efficiency than the Revolizer under standardized conditions. Future studies should include pressure-drop-adjusted or patient-simulated testing to better reflect clinical inhalation profiles and further explore how device mechanics influence drug delivery.

Indexed as

AerolizerDry powder inhalerFormoterol fumarateNext generation impactorRevolizer